Application of a New Dye for Near-Infrared Fluorescence Laparoscopy of the Ureters
- 1 March 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 57 (3) , 407-411
Abstract
BACKGROUND: Ureteral injury during laparoscopic colorectal surgery is a rare but serious complication with a reported incidence rate of 0.66%. The early detection and prevention of ureteral injury is clinically relevant and important. The successful use of preclinical near-infrared fluorophore CW800-CA for real-time intraoperative identification of the anatomical course of the ureters with the use of a laparoscopic fluorescence imaging system is reported. METHODS: The usefulness of this new imaging technique was explored in two 35-kg pigs. Intravenous CW800-CA was administered 10 minutes before fluorescence imaging was conducted with the use of a commercially available laparoscopic fluorescence imaging system. RESULTS: A dose of 1 mg/mL CW800-CA (bolus injection of 3 mL) provided clear delineation of the course of both ureters by using the fluorescence mode of the laparoscope. There were no adverse reactions to the injected dye. CONCLUSION: Near-infrared fluorescence laparoscopy of the ureters, following intravenous CW800-CA administration, is easily applicable and provides real-time identification of the course of the ureters.Keywords
This publication has 12 references indexed in Scilit:
- Intraoperative Near Infrared Fluorescence Guided Identification of the Ureters Using Low Dose Methylene Blue: A First in Human ExperienceJournal of Urology, 2013
- The Prophylactic Use of a Ureteral Stent in Laparoscopic Colorectal SurgeryScandinavian Journal of Surgery, 2013
- Ureteric injury: a challenging condition to diagnose and manageNature Reviews Urology, 2013
- Advanced intraoperative imaging methods for laparoscopic anatomy navigation: an overviewSurgical Endoscopy, 2012
- Fluorescence cholangiography during laparoscopic cholecystectomy: a feasibility study on early biliary tract delineationSurgical Endoscopy, 2012
- Incidence of Iatrogenic Ureteral Injury After Laparoscopic ColectomyArchives of Surgery, 2012
- Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blueSurgery, 2010
- Risks of minimally invasive surgery underestimated: a report of the Dutch Health Care InspectorateSurgical Endoscopy, 2009
- Real-time intraoperative assessment of the extrahepatic bile ducts in rats and pigs using invisible near-infrared fluorescent lightSurgery, 2008
- Real-Time Intraoperative Ureteral Guidance Using Invisible Near-Infrared FluorescenceJournal of Urology, 2007