Spatial Resolution of Single-Cell Exocytosis by Microwell-Based Individually Addressable Thin Film Ultramicroelectrode Arrays
Open Access
- 23 April 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (9) , 4515-4520
Abstract
We report the fabrication and characterization of microwell-based individually addressable microelectrode arrays (MEAs) and their application to spatially and temporally resolved detection of neurotransmitter release across a single pheochromocytoma (PC12) cell. The microwell-based MEAs consist of 16 4-μm-width square ultramicroelectrodes, 25 3-μm-width square ultramicroelectrodes, or 36 2-μm-width square ultramicroelectrodes, all inside a 40 × 40 μm square SU-8 microwell. MEAs were fabricated on glass substrates by photolithography, thin film deposition, and reactive ion etching. The ultramicroelectrodes in each MEA are tightly defined in a 30 × 30 μm square area, which is further encased inside the SU-8 microwell. With this method, we demonstrate that these microelectrodes are stable, reproducible, and demonstrate good electrochemical properties using cyclic voltammetry. Effective targeting and culture of a single cell is achieved by combining cell-sized microwell trapping and cell-picking micropipet techniques. The surface of the microelectrodes in the MEA was coated with collagen IV to promote cell adhesion and further single-cell culture, as good adhesion between the cell membrane and the electrode surface is critical for the quality of the measurements. Imaging the spatial distribution of exocytosis at the surface of a single PC12 cell has also been demonstrated with this system. Exocytotic signals have been successfully recorded from eight independent 2-μm-wide ultramicroelectrodes from a single PC12 cell showing that the subcellular heterogeneity in single-cell exocytosis can be precisely analyzed with these microwell-based MEAs.Keywords
This publication has 32 references indexed in Scilit:
- Individually Addressable Thin-Film Ultramicroelectrode Array for Spatial Measurements of Single Vesicle ReleaseAnalytical Chemistry, 2013
- Parallel On-Chip Analysis of Single Vesicle Neurotransmitter ReleaseAnalytical Chemistry, 2013
- Topographical and electrochemical nanoscale imaging of living cells using voltage-switching mode scanning electrochemical microscopyProceedings of the National Academy of Sciences, 2012
- Carbon-Ring Microelectrode Arrays for Electrochemical Imaging of Single Cell Exocytosis: Fabrication and CharacterizationAnalytical Chemistry, 2012
- Microwell Device for Targeting Single Cells to Electrochemical Microelectrodes for High-Throughput Amperometric Detection of Quantal ExocytosisAnalytical Chemistry, 2011
- Improved Surface-Patterned Platinum Microelectrodes for the Study of Exocytotic EventsAnalytical Chemistry, 2009
- Electrically evoking and electrochemically resolving quantal release on a microchipLab on a Chip, 2009
- Magnetron sputtered diamond-like carbon microelectrodes for on-chip measurement of quantal catecholamine release from cellsBiomedical Microdevices, 2008
- Spatially and Temporally Resolved Single-Cell Exocytosis Utilizing Individually Addressable Carbon Microelectrode ArraysAnalytical Chemistry, 2008
- Controlled on-chip stimulation of quantal catecholamine release from chromaffin cells using photolysis of caged Ca2+on transparent indium-tin-oxide microchip electrodesLab on a Chip, 2007