Does Fluoroscopy With Anterior Hip Arthoplasty Decrease Acetabular Cup Variability Compared With a Nonguided Posterior Approach?
- 1 June 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 472 (6) , 1877-1885
Abstract
The direct anterior approach for THA offers some advantages, but is associated with a significant learning curve. Some of the technical difficulties can be addressed by the use of intraoperative fluoroscopy which may improve the accuracy of acetabular component placement. The purposes of this study were to determine if (1) there is decreased variability of acetabular cup inclination and anteversion with the direct anterior approach using fluoroscopic guidance as compared with the posterior approach THA without radiographic guidance; (2) if there is a learning curve associated with achieving accuracy with the direct anterior approach THA. We also wanted (3) to assess the frequency of complications including dislocation with the anterior approach, which initially had a learning curve, and the posterior approach. This retrospective, comparative study of 825 THAs (372 posterior THAs without fluoroscopic guidance and 453 direct anterior THAs, performed by one surgeon, focused on a radiographic analysis to determine cup inclination and anteversion on standardized pelvic radiographs using specialized software. The first 100 direct anterior THAs performed while transitioning from the posterior approach to the direct anterior approach were included in the learning curve group. During this learning curve period, the direct anterior approach was used for all patients except those with conversion of previously fixed intertrochanteric or femoral neck fractures to THAs, gluteus medius tears, and obese patients with an immobile abdominal pannus (100 of 127 THAs). Variability of the acetabular component was compared among the posterior group, learning curve group, and direct anterior group. Variances for cup inclination and anteversion were significantly lower in the direct anterior group (19 and 16 respectively, p < 0.01) as compared with the posterior group (50 and 79 respectively).Target inclination and anteversion were achieved better in the direct anterior group (98% and 97% respectively) as compared with the posterior group (86% and 77% respectively) (p < 0.01, OR for inclination = 9.1, 95% CI, 3.5 to 23.4; OR for anteversion = 8, 95% CI, 4 to 16). In the learning curve group, target anteversion achieved (91% of cases) was marginally lower than that of the direct anterior group (p = 0.03; OR = 2.9, 95% CI, 1.1 to 7.3) and target inclination (95%) was similar (p = 0.13). There was one posterior dislocation in the posterior group, two anterior dislocations in the learning curve group, and none in the direct anterior group. Use of fluoroscopy with the patient in the supine position during direct anterior THA enables intraoperative assessment of cup orientation resulting in decreased variability of acetabular cup anteversion. However, there is a learning curve associated with achieving this accuracy. We could not discern whether this difference was the result of the approach or the use of fluoroscopy in the direct anterior group. Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 28 references indexed in Scilit:
- Preoperative Fluoroscopic Imaging Reduces Variability of Acetabular Component PositioningThe Journal of Arthroplasty, 2011
- Is There Faster Recovery With an Anterior or Anterolateral THA? A Pilot StudyClinical Orthopaedics and Related Research, 2010
- Quantification of Pelvic Tilt in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- Acetabular Polyethylene Wear and Acetabular Inclination and Femoral OffsetClinical Orthopaedics and Related Research, 2009
- Primary Total Hip Arthroplasty Using an Anterior Approach and a Fracture TableThe Journal of Arthroplasty, 2009
- Reducing the risk of dislocation after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- Mini-incision Anterior Approach Does Not Increase Dislocation RateClinical Orthopaedics and Related Research, 2004
- Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized studyComputer Aided Surgery, 2002
- Reduction in Variability of Acetabular Cup Abduction Using Computer Assisted Surgery: A Prospective and Randomized StudyComputer Aided Surgery, 2002
- Modern technique of cemented total hip arthroplastyTechniques in Orthopaedics, 1991