Corrosion Performance of Fe-Cr-Ni Alloys in Artificial Saliva and Mouthwash Solution
Open Access
- 1 January 2015
- journal article
- research article
- Published by Wiley in Bioinorganic Chemistry and Applications
- Vol. 2015, 1-14
Abstract
Several austenitic stainless steels suitable for high temperature applications because of their high corrosion resistance and excellent mechanical properties were investigated as biomaterials for dental use. The steels were evaluated by electrochemical techniques such as potentiodynamic polarization curves, cyclic polarization curves, measurements of open circuit potential, and linear polarization resistance. The performance of steels was evaluated in two types of environments: artificial saliva and mouthwash solution at 37°C for 48 hours. In order to compare the behavior of steels, titanium a material commonly used in dental applications was also tested in the same conditions. Results show that tested steels have characteristics that may make them attractive as biomaterials for dental applications. Contents of Cr, Ni, and other minor alloying elements (Mo, Ti, and Nb) determine the performance of stainless steels. In artificial saliva steels show a corrosion rate of the same order of magnitude as titanium and in mouthwash have greater corrosion resistance than titanium.Keywords
Funding Information
- Secretaría de Ciencia, Humanidades, Tecnología e Innovación (198687)
This publication has 36 references indexed in Scilit:
- The corrosion behaviour of austenitic and duplex stainless steels in artificial saliva with the addition of fluorideCorrosion Science, 2011
- Influence of fluoride ion on the electrochemical behaviour of β-Ti alloy for dental implant applicationCorrosion Science, 2010
- Corrosion behaviour of a dental alloy in some beverages and drinksMaterials Chemistry and Physics, 2009
- Development of an Artificial Saliva Solution for Studying the Corrosion Behavior of Dental AlloysCorrosion, 2004
- Corrosion of bio implantsSādhanā, 2003
- Effect of fluoride and albumin concentration on the corrosion behavior of Ti–6Al–4V alloyBiomaterials, 2003
- Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopyCorrosion Science, 2001
- Corrosion Behavior of Pure Titanium and Titanium Alloys in Fluoride-containing Solutions.Dental Materials Journal, 2001
- Critical Evaluation of the Composition and Use of Topical FluoridesJournal of Dental Research, 1990
- Fracture of titanium orthopaedic implantsJournal of Materials Science, 1982