Abstract
Reinforced concrete columns are common and essential structural members in reinforced concrete structures, such as building columns, bridge abutments, bridge piers, and bridge pylons. The failure of a column can lead to progressive collapse throughout the entire structure, causing significant human and economic losses. Therefore, reinforced concrete columns are often designed with a greater strength reserve compared to flexural and shear members. This study presents a method for constructing the M-P interaction diagram for reinforced concrete columns with complex cross-sections according to TCVN 11823-2017. First, the structural characteristics of reinforced concrete columns and the theoretical basis for calculating reinforced concrete columns with complex cross-sections according to TCVN 11823-2017 are presented in detail. Next, two examples are provided to illustrate the application of theoretical formulas in developing the M-P interaction diagram for reinforced concrete columns with hollow circular cross-section and hollow oval cross-section. The results show that the M-P interaction diagram of a column with a hollow oval cross-section exhibits similar characteristics to the M-P interaction diagrams of conventional solid reinforced concrete columns. This study is expected to serve as a useful reference for researchers and engineers interested in the design and calculation of reinforced concrete columns with complex cross-sections according to TCVN 11823-2017