Differential-pulse adsorptive stripping voltammetry of the diuretic torasemide at a hanging mercury drop electrode
Authors:
- Marta FernándezMFMarta Fernández
- Rosa M. AlonsoRARosa M. Alonso
- Rosa M. JiménezRJRosa M. Jiménez
- Maria J. LegorburuMLMaria J. Legorburu
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 119 (2) , 319-322
Abstract
A method is described for the determination of torasemide, a loop diuretic, by differential-pulse adsorptive stripping voltammetry at a hanging mercury drop electrode. Accumulation of this diuretic was found to be optimized in Britton–Robinson buffer (pH 2.50) solution with the following conditions: accumulation potential, –900 mV; accumulation time, 30 s; and rest time, 10 s. Under these conditions, the current showed a linear dependence with concentration in the range 2.29 × 10–7–3.65 × 10–6 mol l–1. The reproducibility, in terms of relative standard deviation, for 10 determinations of 4.89 × 10–7 and 9.83 × 10–7 mol l–1 solutions was 1.80 and 0.90%, respectively; the detection limit was 80 ppb (2.29 × 10–7 mol l–1). The method was applied to urine samples spiked with torasemide, to obtain a recovery of 100.6 ± 3.4%.Keywords
This publication has 10 references indexed in Scilit:
- Voltammetric study of the diuretic xipamideBioelectrochemistry and Bioenergetics, 1993
- Oxidative behavior of the sulfonamidic diuretic bumetanide at carbon paste electrodeElectroanalysis, 1993
- Solid-Phase Extraction and Liquid Chromatography of Torsemide and Metabolites from Plasma and UrineJournal of Pharmaceutical Sciences, 1990
- Liquid chromotographic screening of diuretics in urineJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- The determination of torasemide and metabolites in plasma by high-performance liquid chromatographyJournal of Pharmaceutical and Biomedical Analysis, 1987
- Electroanalytical studies of antibacterial and diuretic drugs at rotating disc electrodes of gold and platinumThe Analyst, 1984
- Potentiometric determination of sulfonamides with a silver sulfide electrodeAnalytica Chimica Acta, 1982
- Application of conventional (DC) and differential pulse polarography (DPP) to the quality control of benzothiadiazines in tablets. Simultaneous determination of hydrochlorothiazide and dihydralazine sulphate in mixtures with minimization of interaction byJournal of Pharmacy and Pharmacology, 1982
- Determination of sulpha-drugs with ion-selective membrane electrodesTalanta, 1981
- Direct current and alternating current polarographic response of some pharmaceuticals in an aprotic organic solvent systemAnalytical Chemistry, 1970