Maximum Voltage Utilization of IPMSMs Using Modulating Voltage Scalability for Automotive Applications
Authors:
- 26 March 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 28 (12) , 5639-5646
Abstract
A hybrid maximum voltage utilization controller is developed for interior permanent-magnet synchronous motors over a wide operating range. The structure of the controller combines the current vector control (CVC)-type maximum torque per ampere controller and the modulating voltage-scaled controller (MVSC). The hybrid structure provides a smooth transition from the CVC to the proposed MVSC mode by deactivating the current regulator in the flux weakening region. A seamless transition to a full six-step modulation can be realized by adjusting the scaling gain, which is a significant merit in terms of power utilization for wide flux weakening applications. This paper also examines the torque control accuracy under motor parameter drifts to determine how to decouple its effect using a voltage disturbance state-filter design.Keywords
This publication has 14 references indexed in Scilit:
- Voltage disturbance state-filter design for precise torque-controlled interior permanent magnet synchronous motors2011
- Topological Overview of Powertrains for Battery-Powered Vehicles With Range ExtendersIEEE Transactions on Power Electronics, 2011
- Minimum-copper-loss control over full speed range of an IPMSM drive for hybrid electric vehicle application2010
- Torque Feedforward Control Technique for Permanent-Magnet Synchronous MotorsIEEE Transactions on Industrial Electronics, 2010
- Steady-State and Transient Operation of IPMSMs Under Maximum-Torque-per-Ampere ControlIEEE Transactions on Industry Applications, 2009
- Advances on IPM technology for hybrid electric vehicles2009
- Sensorless control of interior permanent-magnet machine drives with zero-phase lag position estimationIEEE Transactions on Industry Applications, 2003
- Impact of saturation and inverter cost on interior PM synchronous machine drive optimizationIEEE Transactions on Industry Applications, 2000
- Dynamic overmodulation characteristics of triangle intersection PWM methodsIEEE Transactions on Industry Applications, 1999
- Overmodulation strategy for high-performance torque controlIEEE Transactions on Power Electronics, 1998