A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Open Access
- 1 May 2025
- journal article
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (3) , 202-211
Abstract
Purpose: This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.Methods: This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).Results: In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771, P=0.609).Conclusion: The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.Keywords
Funding Information
- Canon Medical Systems Corporation (2023-CMSK-UL002)
This publication has 32 references indexed in Scilit:
- The most appropriate region-of-interest position for attenuation coefficient measurement in the evaluation of liver steatosisJournal of Medical Ultrasonics, 2021
- Performance of the Attenuation Imaging Technology in the Detection of Liver SteatosisJournal of Ultrasound in Medicine, 2020
- Prospective, Same-Day, Direct Comparison of Controlled Attenuation Parameter With the M vs the XL Probe in Patients With Nonalcoholic Fatty Liver Disease, Using Magnetic Resonance Imaging–Proton Density Fat Fraction as the StandardClinical Gastroenterology and Hepatology, 2019
- Noninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH TrialsHepatology, 2018
- Optimal threshold of controlled attenuation parameter with MRI‐PDFF as the gold standard for the detection of hepatic steatosisHepatology, 2017
- Controlled Attenuation Parameter (CAP) with the XL Probe of the Fibroscan®: A Comparative Study with the M Probe and Liver BiopsyDigestive Diseases and Sciences, 2017
- Fibrosis Progression in Nonalcoholic Fatty Liver vs Nonalcoholic Steatohepatitis: A Systematic Review and Meta-analysis of Paired-Biopsy StudiesClinical Gastroenterology and Hepatology, 2015
- Ezetimibe for the treatment of nonalcoholic steatohepatitis: Assessment by novel magnetic resonance imaging and magnetic resonance elastography in a randomized trial (MOZART trial)Hepatology, 2014
- Liver biopsy†Hepatology, 2009
- Design and validation of a histological scoring system for nonalcoholic fatty liver disease†Hepatology, 2005