The zlog value as a basis for the standardization of laboratory results
Open Access
- 1 January 2017
- journal article
- research article
- Published by Walter de Gruyter GmbH in Journal of Laboratory Medicine
- Vol. 41 (s1)
Abstract
Background: With regard to the German E-Health Law of 2016, the German Society for Clinical Chemistry and Laboratory Medicine (DGKL) has been invited to develop a standard procedure for the storage and transmission of laboratory results. We suggest the commonly used z-transformation. Methods: This method evaluates by how many standard deviations (SDs) a given result deviates from the mean of the respective reference population. We confirm with real data that laboratory results of healthy individuals can be adjusted to a normal distribution by logarithmic transformation. Results: Thus, knowing the lower and upper reference limits LL and UL, one can transform any result x into a zlog value using the following equation: zlog = (log(x) – (log(LL) + log(UL))/2)·3 .92/(log(UL) – log(LL)) $\eqalign{ {\rm{zlog}} = & {\rm{(log(x)}}-{\rm{(log(LL)}} + {\rm{log(UL))/2)\cdot3}}{\rm{.92/(log(UL)}} \cr -{\bf{ }}{\rm{log(LL))}} \cr} $ The result can easily be interpreted, as its reference interval (RI) is –1.96 to +1.96 by default, and very low or high results yield zlog values around –5 and +5, respectively. For intuitive data presentation, the zlog values may be transformed into a continuous color scale, e.g. from blue via white to orange. Using the inverse function, any zlog value can then be translated into the theoretical result of an analytical method with another RI: (1) x = LL 0.5 − zlog / 3.92 ⋅ UL 0.5 + zlog / 3.92 $${\rm{x}} = {\rm{L}}{{\rm{L}}^{0.5 - {\rm{zlog}}/3.92}} \cdot {\rm{U}}{{\rm{L}}^{0.5 + {\rm{zlog}}/3.92}}$$ Conclusions: Our standardization proposal can easily be put into practice and may effectively contribute to data quality and patient safety in the frame of the German E-health law. We suggest for the future that laboratories should provide the zlog value in addition to the original result, and that the data transmission protocols (e.g. HL7, LDT) should contain a special field for this additional value.
Keywords
This publication has 16 references indexed in Scilit:
- The Enhanced Liver Fibrosis (ELF) score: Normal values, influence factors and proposed cut-off valuesJournal of Hepatology, 2013
- Metrological traceability – a concept for standardization in laboratory medicineClinical Chemistry and Laboratory Medicine (CCLM), 2013
- Observed, unknown distributions of clinical chemical quantities should be considered to be log-normal: a proposalClinical Chemistry and Laboratory Medicine (CCLM), 2010
- Data-Mining in klinischen Datensätzen – Bericht der Arbeitsgruppe Bioinformatik der DGKLJournal of Laboratory Medicine, 2010
- Clinical laboratory reference intervals in pediatrics: The CALIPER initiativeClinical Biochemistry, 2009
- A plea for intra-laboratory reference limits. Part 2. A bimodal retrospective concept for determining reference limits from intra-laboratory databases demonstrated by catalytic activity concentrations of enzymesClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Interchangeability of Measurements of Total and Free Prostate-Specific Antigen in Serum with 5 Frequently Used Assay Combinations: An UpdateClinical Chemistry, 2006
- The evolution of the reference value conceptClinical Chemistry and Laboratory Medicine (CCLM), 2004
- IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine AminotransferaseClinical Chemistry and Laboratory Medicine (CCLM), 2002
- Blood haemoglobin declines in the elderly: implications for reference intervals fromage 70 to 88European Journal of Haematology, 2000