Novel Surface Modifications of Carbon Fiber‐Reinforced Polyetheretherketone Hip Stem in an Ovine Model
- 7 August 2011
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 36 (1) , 62-70
Abstract
A carbon fiber‐reinforced polymer (CFRP) is theoretically a suitable material for use in an uncemented hip prosthesis considering it can provide isoelastic environment with the surrounding bone, adequate fatigue strength, and a metal‐free radiographic evaluation. To date, the selection of polymer material and optimization of both design and surface finish of the prostheses for osseointegration has not been accomplished. This study examined radiographic and histologic results of an uncemented CFRP stem manufactured from carbon fiber‐reinforced polyetheretherketone (CFR/PEEK) with a roughened surface and a bioactive treatment in an adult ovine model following a 12‐month implantation period. A unilateral hemiarthroplasty of the hip was performed using the CFRP stem or a titanium stem as a control. Four cases with the CFRP stem and five cases with titanium stem were evaluated. Bone on‐growth fixation was achieved in two cases with the CFRP stem and in all the cases with the titanium stem. The CFRP cases showed minimal stress shielding while three of five cases with the titanium stem demonstrated typical osteopenia associated with stiff metal stems. Bone on‐growth to the uncemented CFRP stem was achieved by using the CFR/PEEK for the material and modifying the surface design and the bioactive surface finish. Bone resorption and osteopenia observed with the Ti stems was not found with the CFRP design.Keywords
This publication has 29 references indexed in Scilit:
- The association between metal allergy, total hip arthroplasty, and revisionActa Orthopaedica, 2009
- Comparison of polyetheretherketone cages with femoral cortical bone allograft as a single-piece interbody spacer in transforaminal lumbar interbody fusionJournal of Neurosurgery: Spine, 2006
- Anterior cervical fusion with polyetheretherketone (PEEK) cages in the treatment of degenerative disc disease. Preliminary observations in 36 consecutive cases with a minimum 12-month follow-upActa Neurochirurgica, 2005
- Bioactive hydroxyapatite coatings on polymer composites for orthopedic implantsJournal of Biomedical Materials Research Part A, 2005
- The future in the care of the cervical spine: interbody fusion and arthroplastyJournal of Neurosurgery: Spine, 2004
- Preliminary Experience Using a Polyetheretherketone (PEEK) Cage in the Treatment of Cervical Disc DiseaseNeurosurgery, 2002
- In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblastsBiomaterials, 1995
- In vitro biocompatibility of polyetheretherketone and polysulfone compositesJournal of Biomedical Materials Research, 1990
- Micromotions in the primary fixation of cementless femoral stem prosthesesArchives of orthopaedic and trauma surgery, 1989
- A Canine Composite Femoral StemClinical Orthopaedics and Related Research, 1988