Partial discharge behavior under operational and anomalous conditions in HVDC systems
Open Access
- 29 June 2017
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 24 (3) , 1494-1502
Abstract
Power cables undergo various types of overstressing conditions during their operation that influence the integrity of their insulation systems. This causes accelerated ageing and might lead to their premature failure in severe cases. This paper presents an investigation of the impacts of various dynamic electric fields produced by ripples, polarity reversal and transient switching impulses on partial discharge (PD) activity within solid dielectrics with the aim of considering such phenomena in high voltage direct current (HVDC) cable systems. Appropriate terminal voltages of a generic HVDC converter were reproduced — with different harmonic contaminations — and applied to the test samples. The effects of systematic operational polarity reversal and superimposed switching impulses with the possibility of transient polarity reversal were also studied in this investigation. The experimental results show that the PD is greatly affected by the dynamic changes of electric field represented by polarity reversal, ripples and switching. The findings of this study will assist in understanding the behaviour of PDs under HVDC conditions and would be of interest to asset managers considering the effects of such conditions on the insulation diagnostics.Keywords
This publication has 22 references indexed in Scilit:
- Finite element model of HVDC converter harmonic effects on partial discharge2016
- Influence of voltage harmonic phenomena on partial discharge behavior at HVDC2016
- Reliability evaluation of insulation subjected to harmonic voltages within the limits set by international standardsIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- The effect of DC superimposed AC voltage on partial discharges in dielectric bounded cavities2014
- Extruded Cables For High‐Voltage Direct‐Current Transmission2013
- The role of HVDC voltage waveforms on partial discharge activity in paper/oil insulation2012
- Experience with Preventing External Flashovers in HVDC Converter Stations2008
- Polymeric HVDC Cable Design and Space Charge Accumulation. Part 1: Insulation/Semicon InterfaceIEEE Electrical Insulation Magazine, 2007
- High Voltage Direct Current Transmission1998
- International research and development trends and problems of HVDC cables with polymeric insulationIEEE Electrical Insulation Magazine, 1997