Relationship between wheelchair durability and wheelchair type and years of test
Authors:
- Hongwu WangHongwu Wang
- Hsin-Yi LiuHLHsin-Yi Liu
- Jon PearlmanJPJon Pearlman
- Rosemarie CooperRCRosemarie Cooper
- Alexandra JefferdsAJAlexandra Jefferds
- Rory A. CooperRCRory A. Cooper
- 7 December 2009
- journal article
- research article
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 5 (5) , 318-322
Abstract
Objective. To investigate the relationship between the durability of wheelchairs according to American National Standard for Wheechairs/Rehabilitation Engineering and Assistive Technology Society of North America (ANSI/RESNA) Wheelchair Standards and wheelchair type as well as year of test. Design. A retrospective study design with a sample of 246 wheelchairs that were tested in accordance with the ANSI/RESNA standards from 1992 to 2008 including four types of wheelchairs: manual wheelchair (MWC), electrical powered wheelchair (EPW), scooters and pushrim-activated power-assisted wheelchair (PAPAW). Unconditional binary logic regression analysis was chosen to evaluate the relationship between test results and test year as well as wheelchair type. Setting. Rehabilitation Engineering Research Center. Main Outcome Measures: Wheelchair durability test result (fatigue test: pass or fail) Results. There was no significant correlation between the year when tested and equivalent cycles. A significant relation was found between test results and wheelchair type (Wald score = 10.845, degree of freedom = 3, p = 0.013) with scooters having a significantly higher pass ratio than MWC (OR = 15.629, 95% CI = 2.026–120.579). EPW also had significantly higher pass ratio than MWC (OR = 1.953, 95% CI = 1.049–3.636). No significant difference on pass ratio was found between PAPAW and MWC. Conclusions. No significant improvements in wheelchair test results during the time frame from 1992 to 2008 were discovered. Wheelchair standard tests should be conducted to assure minimum quality of the wheelchairs and for improving the design of wheelchairs. Although the ANSI/RESNA wheelchair durability test procedures have remained consistent, it does not appear that the introduction of new materials, designs and the availability of test data have improved wheelchair fatigue life.Keywords
This publication has 9 references indexed in Scilit:
- Trends and Issues in Wheelchair TechnologiesAssistive Technology, 2008
- Evaluation of Pushrim-Activated Power-Assisted Wheelchairs Using ANSI/RESNA StandardsArchives of Physical Medicine and Rehabilitation, 2008
- Assessing mobility characteristics and activity levels of manual wheelchair usersJournal of Rehabilitation Research and Development, 2007
- Wheelchair related injuries treated in US emergency departmentsInjury Prevention, 2006
- Fatigue testing of selected suspension manual wheelchairs using ANSI/RESNA standardsArchives of Physical Medicine and Rehabilitation, 2005
- Issues in maintenance and repairs of wheelchairs: A pilot studyJournal of Rehabilitation Research and Development, 2005
- Durability, value, and reliability of selected electric powered wheelchairs11No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit upon the author(s) or upon any organization with which the author(s) is/are associated.Archives of Physical Medicine and Rehabilitation, 2004
- Evaluation of selected electric-powered wheelchairs using the ANSI/RESNA standardsArchives of Physical Medicine and Rehabilitation, 2004
- Comparison of fatigue life for 3 types of manual wheelchairsArchives of Physical Medicine and Rehabilitation, 2001