Nucleic Acid Quantification with Amplicon Yield in Recombinase Polymerase Amplification
Authors:
- 28 September 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (40) , 13897-13905
Abstract
Amplification-based quantitative polymerase chain reaction (qPCR) provides accurate and sensitive nucleic acid quantification. However, the requirement of temperature cycling and real-time monitoring limits its translation to many settings. Quantitative isothermal amplification methods alleviate the need for thermal cyclers; however, they still require continuous monitoring of the nucleic acid amplification on sophisticated readers. Here, we adapted an isothermal recombinase polymerase amplification (RPA) reaction to develop a semiquantitative method that relies on the final amplicon yield to estimate the initial target nucleic acid copy number. To achieve this, we developed a phenomenological model that captures the essential RPA dynamics. We identified reaction conditions that constrained the reaction yield corresponding to the starting DNA template concentration. We validated these predictions experimentally and showed that the amplicon yields at the end of the RPA reaction correlated well with the starting DNA concentration while reducing nonspecific amplification robustly. We demonstrate this approach, termed quantitative endpoint RPA (qeRPA), to detect DNA over five log orders with a detection limit of 100 molecules. Using a linear regression model of the normalized endpoint intensity (NEI) standard curve, we estimate the viral load from the serum of dengue virus-infected patients with comparable performance to qPCR. Unlike the conventional isothermal quantitative methods, qeRPA can be employed for robust and sensitive nucleic acid estimation at close to room temperature without real-time monitoring and can be beneficial for field deployment in resource-limited settings.Keywords
All Related Versions
Funding Information
- Anusandhan National Research Foundation (CRG/2018/004266)
- Indian Institute of Science
- Department of Biotechnology, Ministry of Science and Technology, India (BT/PR13926/MED31/97/2010)
This publication has 33 references indexed in Scilit:
- An Empirical Approach for Quantifying Loop-Mediated Isothermal Amplification (LAMP) Using Escherichia coli as a Model SystemPLOS ONE, 2014
- Quantification of HIV-1 DNA Using Real-Time Recombinase Polymerase AmplificationAnalytical Chemistry, 2014
- Direct observation of individual RecA filaments assembling on single DNA moleculesNature, 2006
- DNA Detection Using Recombination ProteinsPLOS Biology, 2006
- Principles of quantitation of viral loads using nucleic acid sequence-based amplification in combination with homogeneous detection using molecular beaconsNucleic Acids Research, 2002
- Loop-mediated isothermal amplification of DNANucleic Acids Research, 2000
- Real-Time, Sequence-Specific Detection of Nucleic Acids during Strand Displacement AmplificationAnalytical Biochemistry, 1999
- Comparative kinetic analysis of FLP and cre recombinases: mathematical models for DNA binding and recombinationJournal of Molecular Biology, 1998
- Simultaneous Amplification and Detection of Specific DNA SequencesBio/Technology, 1992
- Specific Enzymatic Amplification of DNA In Vitro: The Polymerase Chain ReactionCold Spring Harbor Symposia on Quantitative Biology, 1986