Physically implausible signals as a quantitative quality assessment metric in prostate diffusion-weighted MR imaging
- 18 May 2022
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (7) , 2500-2508
Abstract
Purpose To provide a quantitative assessment of diffusion-weighted MR images of the prostate through identification of PIDS which clearly represents artifacts in the data. We calculated the percentage and distribution of PIDS in prostate DWI and compare the amount of PIDS between mpMRI images obtained with and without an endorectal coil. Methods This IRB approved retrospective study (from 03/03/2014 to 03/10/2020), included 40 patients scanned with endorectal coil (ERC) and 40 without ER coil (NERC). PIDS contains any voxel where: (1) the diffusion signal increases despite an increase in b-value; and/or (2) apparent diffusion coefficient (ADC) is more than 3.0 μm2/ms (the ADC of pure water at 37 °C and it is physically implausible for any material to have a higher ADC). PIDS for transition zone (TZ) and peripheral zone (PZ) was calculated using an in-house MATLAB program. DWI images were quantitatively inspected for noise, motion, and distortion. T-test was used to compare the difference between PIDS levels in ERC versus NERC and ANOVA to compare the PIDS levels in the anatomic zones. The images were evaluated by a fellowship-trained radiologist in Abdominal Imaging with more than 10 years of experience in reading prostate MRI. This was tested only in prostate in this study. Results 80 patients (58 ± 8 years old, 80 men) were evaluated. The percentage of voxels exhibiting PIDS was 17.1 ± 8.1% for the ERC cohort and 22.2 ± 15.5% for the NERC cohort. PIDS for NERC versus ERC were not significantly different (p = 0.14). The apex and base showed similar percentages of PIDS in ERC (p = 0.30) and NERC (p = 0.86). The mid (13.8 ± 8.6%) in ERC showed lower values (p = 0.02) of PIDS compared to apex (19.9 ± 11.1%) and base (17.5 ± 8.3%). Conclusion PIDS maps provide a spatially resolved quantitative quality assessment for prostate DWI. Average PIDS over the entire prostate were similar for the ERC and NERC cohorts, and did not differ significantly across prostate zones. However, for many of the patients, PIDS was focally much higher in specific prostate zones. PIDS assessment can guide Radiologist’s evaluation of images and the development of improved DWI sequences.Keywords
Funding Information
- National Institutes of Health (R01 CA227036, 1R41CA244056-01A1, R01 CA17280, 1S10OD018448-01)
- Sanford J. Grossman Charitable Trust
- University of Chicago Medicine Comprehensive Cancer Center (P30 CA014599-37)
This publication has 23 references indexed in Scilit:
- Accuracy of Multiparametric MRI for Prostate Cancer Detection: A Meta-AnalysisAmerican Journal of Roentgenology, 2014
- Quantitative Evaluation of Computed High b Value Diffusion-Weighted Magnetic Resonance Imaging of the ProstateInvestigative Radiology, 2013
- Hybrid multidimensional T2 and diffusion‐weighted MRI for prostate cancer detectionJournal of Magnetic Resonance Imaging, 2013
- Noise measurement from magnitude MRI using local estimates of variance and skewnessPhysics in Medicine & Biology, 2010
- Automatic quality assessment in structural brain magnetic resonance imagingMagnetic Resonance in Medicine, 2009
- Quantitative image quality evaluation of MR images using perceptual difference modelsMedical Physics, 2008
- Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRIMagnetic Resonance in Medicine, 2003
- Temperature Dependent Change of Apparent Diffusion Coefficient of Water in Normal and Ischemic Brain of RatsJournal of Cerebral Blood Flow & Metabolism, 1994
- General expressions for Rician density and distribution functionsIEEE Transactions on Aerospace and Electronic Systems, 1993
- Motion artifact suppression: A review of post-processing techniquesMagnetic Resonance Imaging, 1992