On the Uniqueness of the Receding Contact Angle: Effects of Substrate Roughness and Humidity on Evaporation of Water Drops
- 29 July 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (31) , 9346-9354
Abstract
Could a unique receding contact angle be indicated for describing the wetting properties of a real gas–liquid–solid system? Could a receding contact angle be defined if the triple line of a sessile drop is not moving at all during the whole measurement process? To what extent is the receding contact angle influenced by the intrinsic properties of the system or the measurement procedures? In order to answer these questions, a systematic investigation was conducted in this study on the effects of substrate roughness and relative humidity on the behavior of pure water drops spreading and evaporating on polycarbonate (PC) surfaces characterized by different morphologies. Dynamic, advancing, and receding contact angles were found to be strongly affected by substrate roughness. Specifically, a receding contact angle could not be measured at all for drops evaporating on the more rugged PC surfaces, since the drops were observed strongly pinning to the substrate almost until their complete disappearance. Substrate roughness and system relative humidity were also found responsible for drastic changes in the depinning time (from ∼10 to ∼60 min). Thus, for measurement observations not sufficiently long, no movement of the triple line could be noted, with, again, the failure to find a receding contact angle. Therefore, to keep using concepts such as the receding contact angle as meaningful specifications of a given gas–liquid–solid system, the imperative to carefully investigate and report the inner characteristics of the system (substrate roughness, topography, impurities, defects, chemical properties, etc.) is pointed out in this study. The necessity of establishing methodological standards (drop size, measurement method, system history, observation interval, relative humidity, etc.) is also suggested.Keywords
Funding Information
- National Science Council Taiwan (100-2221-E-011-101)
This publication has 54 references indexed in Scilit:
- Evaporation of pure liquid sessile and spherical suspended drops: A reviewAdvances in Colloid and Interface Science, 2012
- Evaporation of droplets on strongly and weakly pinning surfaces and dynamics of the triple lineColloids and Surfaces A: Physicochemical and Engineering Aspects, 2011
- On the Nature of the Friction between Nonstick Droplets and Solid SubstratesLangmuir, 2010
- Transition in the Evaporation Kinetics of Water Microdrops on Hydrophilic SurfacesLangmuir, 2008
- Influence of heating temperature and relative humidity in the evaporation of pinned dropletsColloids and Surfaces A: Physicochemical and Engineering Aspects, 2008
- Contact Angle Hysteresis on Polymer Substrates Established with Various Experimental Techniques, Its Interpretation, and Quantitative CharacterizationLangmuir, 2008
- On the role of energy barriers in determining contact angle hysteresisAdvances in Colloid and Interface Science, 2006
- Drops Down the Hill: Theoretical Study of Limiting Contact Angles and the Hysteresis Range on a Tilted PlateLangmuir, 2005
- Influence of Evaporation on Contact AngleLangmuir, 1995
- Simple Theory of "Stick-Slip" Wetting HysteresisLangmuir, 1995