Pilot Study: Fibrin Sealant in Anal Fistula Model
Authors:
- Gordon N. BuchananGBGordon N. Buchanan
- Paul SibbonsPSPaul Sibbons
- Mike OsbornMOMike Osborn
- Clive I. BartramCBClive I. Bartram
- Tahera AnsariTATahera Ansari
- Steve HalliganSHSteve Halligan
- C. Richard G. CohenCCC. Richard G. Cohen
- 1 March 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 48 (3) , 532-539
Abstract
Ge in each of eight male pigs. After 26 days, magnetic resonance imaging was performed and setons were removed. Two pigs were killed as controls for stereologic histologic fistula track assessment. In six, fistulas were curetted, and in four the fistulas were treated with fibrin sealant. In these four sealant and two seton pigs, magnetic resonance imaging was repeated a median of 47.5 days after fistula formation. The pigs were killed and stereologic histologic fistula track examination was performed to determine granulation tissue and fistula lumen volumes. These values were compared among control, seton, and sealant groups over time, and related to fistula volumes derived from magnetic resonance imaging. RESULTS: Sealant was not visible microscopically within tracks, although some sections revealed a foreign body-type reaction. On stereologic assessment, granulation tissue volumes were smaller in sealant and seton groups than in controls (median, 88vs.187vs.453 mm3, respectively;P= 0.002) and decreased over time (median, 408 and 152 mm3 (Day 42)vs.88 and 75 (Day 53), respectively;P= 0.002). Fistula lumen (P< 0.001), and granulation tissue combined with fistula lumen volumes (P= 0.002) were similarly smaller. Magnetic resonance imaging of fistula intensity was less in the sealant group than in the seton group and controls (mean, 777vs.978vs.1214 units/mm2,P= 0.003). Magnetic resonance imaging fistula volumes were least in sealant and seton groupsvs.controls (P= 0.024), decreasing significantly in the sealant group over time (P= 0.018). No direct relationship was found between imaging and histologic volumes. CONCLUSIONS: In an experimental porcine model of anal fistula, granulation tissue was still present, albeit diminished, following track curettage combined with seton or sealant therapy, and was minimal in the sealant group, confirming some benefit from this procedure. Eradication of all longstanding granulation tissue may ensure complete success of fibrin sealant therapy. G.N.B. was supported by The St. Mark's Hospital Foundation. Baxter Healthcare provided fibrin sealant in this study. Published online: 31 January 2005 aSt. Mark's Hospital, Watford Road, Harrow, United Kingdom, HA1 3UJ, e-mail: richard.cohen@tesco.net © The ASCRS 2005...Keywords
This publication has 19 references indexed in Scilit:
- Efficacy of Fibrin Sealant in the Management of Complex Anal FistulaDiseases of the Colon & Rectum, 2003
- Outcomes of Primary Repair of Anorectal and Rectovaginal Fistulas Using the Endorectal Advancement FlapDiseases of the Colon & Rectum, 2002
- Repair of fistulas-in-ano using fibrin adhesiveDiseases of the Colon & Rectum, 2000
- Fibrin Glue-Antibiotic Mixture in the Treatment of Anal Fistulae: Experience with 69 CasesDigestive Surgery, 2000
- Fibrin glue application in the treatment of recurrent anorectal fistulasDiseases of the Colon & Rectum, 1999
- Persistence of idiopathic anal fistula may be related to epithelializationBritish Journal of Surgery, 1995
- Histological and microbiological assessment of the role of microorganisms in chronic anal fistulaBritish Journal of Surgery, 1993
- Magnetic resonance imaging of anal fistulaeThe Lancet, 1992
- Bacteriology of anal fistulaeBritish Journal of Surgery, 1992
- Can the external anal sphincter be preserved in the treatment of trans-sphincteric fistula-in-ano?International Journal of Colorectal Disease, 1989