Comparing the compensatory reserve metric obtained from invasive arterial measurements and photoplethysmographic volume-clamp during simulated hemorrhage
Authors:
- 11 May 2024
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (6) , 1337-1346
Abstract
Purpose The compensatory reserve metric (CRM) is a novel tool to predict cardiovascular decompensation during hemorrhage. The CRM is traditionally computed using waveforms obtained from photoplethysmographic volume-clamp (PPGVC), yet invasive arterial pressures may be uniquely available. We aimed to examine the level of agreement of CRM values computed from invasive arterial-derived waveforms and values computed from PPGVC-derived waveforms. Methods Sixty-nine participants underwent graded lower body negative pressure to simulate hemorrhage. Waveform measurements from a brachial arterial catheter and PPGVC finger-cuff were collected. A PPGVC brachial waveform was reconstructed from the PPGVC finger waveform. Thereafter, CRM values were computed using a deep one-dimensional convolutional neural network for each of the following source waveforms; (1) invasive arterial, (2) PPGVC brachial, and (3) PPGVC finger. Bland-Altman analyses were used to determine the level of agreement between invasive arterial CRM values and PPGVC CRM values, with results presented as the Mean Bias [95% Limits of Agreement]. Results The mean bias between invasive arterial- and PPGVC brachial CRM values at rest, an applied pressure of -45mmHg, and at tolerance was 6% [-17%, 29%], 1% [-28%, 30%], and 0% [-25%, 25%], respectively. Additionally, the mean bias between invasive arterial- and PPGVC finger CRM values at rest, applied pressure of -45mmHg, and tolerance was 2% [-22%, 26%], 8% [-19%, 35%], and 5% [-15%, 25%], respectively. Conclusion There is generally good agreement between CRM values obtained from invasive arterial waveforms and values obtained from PPGVC waveforms. Invasive arterial waveforms may serve as an alternative for computation of the CRM.Keywords
Funding Information
- Congressionally Directed Medical Research Programs (DM180240, DM180240)
This publication has 40 references indexed in Scilit:
- Clinical assessment of hemodynamically unstable patientsCurrent Opinion in Critical Care, 2009
- Methods of Monitoring ShockSeminars in Respiratory and Critical Care Medicine, 2004
- Strategies for minimizing blood loss in orthopedic surgerySeminars in Hematology, 2004
- Hemodynamic monitoring in the intensive care unitClinics in Chest Medicine, 2003
- Clinical review: Complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicineCritical Care, 2002
- Volume Replacement in Critically Ill Patients with Acute Renal FailureJournal of the American Society of Nephrology, 2001
- Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients.1998
- Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure MeasurementsCirculation, 1996
- Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.Hypertension, 1989
- Fluid resuscitation in circulatory shock: a comparison of the cardiorespiratory effects of albumin, hetastarch, and saline solutions in patients with hypovolemic and septic shock.1983