Abstract
The design of the mosque building influences the level of comfort for the congregation in worship, including thermal comfort. Located in a dense area, the Saminah Sihyadi Mosque applies a passive design to provide thermal comforts, such as a vast opening system. This article aims to study the condition of natural ventilation in the Saminah Sihyadi Mosque and the opening system applied according to Indonesian standards. The research measured the temperature, humidity, and wind velocity using an Environment Meter. Measurements were conducted five times, following the order of the prayer times over two days with different types of opening. The measurement results are compared with Indonesian National Standards (Standar Nasional Indonesia or SNI) to determine the suitability of the comfort level. The Saminah Sihyadi Mosque has sufficient openings according to standards. The measurement results show that the passive design can reduce the temperature and humidity inside the mosque compared to conditions outside the mosque. The wind moved at a speed that meets thermal comfort standards, ensuring that the implemented passive design successfully regulates thermal comfort.Keywords
This publication has 26 references indexed in Scilit:
- An investigation of indoor thermal environments and thermal comfort in naturally ventilated educational buildingsJournal of Building Engineering, 2024
- Research on thermal comfort of obese and overweight people during indoor running exerciseBuilding and Environment, 2023
- An adaptive neural fuzzy interface structure optimisation for prediction of energy consumption and airflow of a ventilation systemApplied Energy, 2023
- Affordable retrofitting methods to achieve thermal comfort for a terrace house in Malaysia with a hot–humid climateEnergy and Buildings, 2020
- Long-term monitoring data from a naturally ventilated office buildingScientific Data, 2019
- Effectiveness of free running passive cooling strategies for indoor thermal environments: Example from a two-storey corner terrace house in MalaysiaBuilding and Environment, 2019
- Evolving houses, demanding practices: A case of rising electricity consumption of the middle class in PakistanBuilding and Environment, 2018
- Adaptive thermal comfort in university classrooms in Malaysia and JapanBuilding and Environment, 2017
- Thermal comfort and occupant adaptive behaviour in Japanese university buildings with free running and cooling mode offices during summerBuilding and Environment, 2016
- Communal Mosques: Design Functionality towards the Development of Sustainability for CommunityProcedia - Social and Behavioral Sciences, 2014