Simultaneous determination of three major lignans in rat plasma by LC‐MS/MS and its application to a pharmacokinetic study after oral administration of Diphylleia sinensis extract
- 14 October 2013
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 28 (4) , 463-467
Abstract
A sensitive and selective liquid chromatography tandem mass spectrometry was developed and validated for the simultaneous determination of three major lignans (podophyllotoxin, epipodophyllotoxin, and 4′‐demethylpodophyllotoxin) in rat plasma using diphenhydramine as the internal standard. The analytes were detected using a triple quadrupole mass spectrometer that was equipped with an electrospray ionization source in the positive ion and selected reaction monitoring modes. The linearity of the calibration curve was good, with coefficients of determination (r2) >0.9914 for all of the analytes. The developed method was successfully applied for the simultaneous determination of the three lignans in rat plasma following oral administration of Diphylleia sinensis extract to rats. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 11 references indexed in Scilit:
- Determination of picropodophyllin and its isomer podophyllotoxin in human serum samples with electrospray ionization of hexylamine adducts by liquid chromatography–tandem mass spectrometryJournal of Chromatography B, 2011
- Synthesis and biological evaluation of new spin-labeled derivatives of podophyllotoxinBioorganic & Medicinal Chemistry, 2006
- Podophyllotoxin: distribution, sources, applications and new cytotoxic derivativesToxicon, 2004
- Synthesis and cytotoxicity of podophyllotoxin analogues modified in the A ringEuropean Journal of Medicinal Chemistry, 2003
- Production of podophyllotoxin by plant cell cultures of Podophyllum hexandrum in bioreactorJournal of Bioscience and Bioengineering, 2002
- Simultaneous determination of etoposide and its catechol metabolite in the plasma of pediatric patients by liquid chromatography/tandem mass spectrometryJournal of Mass Spectrometry, 2001
- Highly sensitive liquid chromatography–electrospray mass spectrometry (LC–MS) method for the determination of etoposide levels in human serum and plasmaJournal of Chromatography B: Biomedical Sciences and Applications, 2000
- In vivo immunosuppressive activity of some cyclolignansBioorganic & Medicinal Chemistry Letters, 1997
- Determination of a new podophyllotoxin derivative, TOP-53, and its metabolite in rat plasma and urine by high-performance liquid chromatography with electrochemical detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1997
- Activity of NK 611, a new epipodophyllotoxin derivative, against colony forming units from freshly explanted human tumours in vitroEuropean Journal of Cancer, 1995