Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges
Authors:
Open Access
- 26 October 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (10) , e0206435
Abstract
The aim of this study was to identify anatomical indication ranges for different lateral wall cochlear implant electrodes to support surgeons in the preoperative preparation. 272 patients who were implanted with a FLEX20, FLEX24, FLEX28, or a custom-made device (CMD) were included in this study. The cochlear duct length (CDL) and basal cochlear diameter (length A) were measured within preoperative imaging data. The parameter A was then employed to additionally compute CDL estimates using literature approaches. Moreover, the inserted electrode length (IEL) and insertion angle (IA) were measured in postoperative CT data. By combining the preoperative measurements with the IA data, the covered cochlea length (CCL) and relative cochlear coverage (CC) were determined for each cochlea. The measurements of the CDL show comparable results to previous studies. While CDL measurements and estimations cover similar ranges overall, severe deviations occur in individual cases. The electrode specific IEL and CCL are fairly consistent and increase with longer electrodes, but relatively wide ranges of electrode specific CC values were found due to the additional dependence on the respective CDL. Using the correlation of IEL and CCL across electrode arrays, CDL ranges for selected arrays were developed (FLEX24: 31.3–34.4, FLEX28: 36.2–40.1, FLEXSoft: 40.6–44.9). Our analysis shows that electrode specific CC varies due to the CDL variation. Preoperative measurement of the CDL allows for an individualized implant length selection yielding optimized stimulation and a reduced risk of intraoperative trauma. The CDL, as derived from preoperative CT imaging studies, can help the implant surgeon select the appropriate electrode array to maximize the patient’s outcomes.Keywords
This publication has 35 references indexed in Scilit:
- An overview of cochlear implant electrode array designsHearing Research, 2017
- Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode ArraysOtology & Neurotology, 2017
- Evaluation of Rigid Cochlear Models for Measuring Cochlear Implant Electrode PositionOtology & Neurotology, 2016
- Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear ImplantationOtology & Neurotology, 2016
- The diagnostic value of measurement of cochlear length and height in temporal bone CT multiplanar reconstruction of inner ear malformationActa Oto-Laryngologica, 2016
- Optimal electrode length to match patient specific cochlear anatomyEuropean Annals of Otorhinolaryngology, Head and Neck Diseases, 2016
- Visualization, measurement and modelling of the cochlea using rotating midmodiolar slice planesInternational Journal of Computer Assisted Radiology and Surgery, 2016
- Cochlear length determination using Cone Beam Computed Tomography in a clinical settingHearing Research, 2014
- Variational Anatomy of the Human CochleaOtology & Neurotology, 2009
- Sex differences in the length of the organ of Corti in humansThe Journal of the Acoustical Society of America, 2007