Oral decontamination techniques and ventilator-associated pneumonia
Authors:
- 8 June 2017
- journal article
- research article
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 26 (11) , 594-599
Abstract
Ventilator-associated pneumonia (VAP) is one of the major nosocomial infections in the intensive care unit (ICU), contributing to increased mortality and morbidity. Studies have shown that oral decontamination through the use of mechanical and pharmacological agents significantly reduces the incidence of VAP, but oral care practices in ICUs are not consistent. A double-blind randomised controlled trial was undertaken in the medical ICU of a tertiary care centre in India, to assess the efficacy of a toothbrush-based oral care technique in reducing incidence of VAP. Tooth-brushing with concurrent suctioning technique was not proved to be superior to mouth-swabbing. The greatest risk factor for developing VAP was the number of ventilator days (length of time on a ventilator). There was a statistical association between gender and presence of antibiotics with VAP.Keywords
This publication has 22 references indexed in Scilit:
- The Intensive Care Society recommended bundle of interventions for the prevention of ventilator-associated pneumoniaJournal of the Intensive Care Society, 2016
- The Hawthorne Effect in Infection Prevention and EpidemiologyInfection Control & Hospital Epidemiology, 2015
- Effects of three approaches to standardized oral hygiene to reduce bacterial colonization and ventilator associated pneumonia in mechanically ventilated patients: A randomised control trialInternational Journal of Nursing Studies, 2011
- Oral Care Practices for Orally Intubated Critically Ill AdultsAmerican Journal of Critical Care, 2010
- Oral Care Intervention to Reduce Incidence of Ventilator-Associated Pneumonia in the Neurologic Intensive Care UnitJournal of Neuroscience Nursing, 2008
- Oral decontamination for prevention of pneumonia in mechanically ventilated adults: systematic review and meta-analysisBMJ, 2007
- Colonization of Dental PlaquesChest, 2004
- Evidence-Based Clinical Practice Guideline for the Prevention of Ventilator-Associated PneumoniaAnnals of Internal Medicine, 2004
- Protocol-Driven Ventilator Weaning Reduces Use of Mechanical Ventilation, Rate of Early Reintubation, and Ventilator-Associated Pneumonia2004
- Chlorhexidine Gluconate 0.12% Oral Rinse Reduces the Incidence of Total Nosocomial Respiratory Infection and Nonprophylactic Systemic Antibiotic Use in Patients Undergoing Heart SurgeryChest, 1996