Model-Based Assessment of Tissue Perfusion and Temperature in Deep Hypothermic Patients
- 3 May 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (7) , 1577-1586
Abstract
Deep hypothermic circulatory arrest is necessary for some types of cardiac and aortic surgery. Perfusion of the brain can be maintained using a heart-lung machine and unilateral antegrade cerebral perfusion. Cooling rates during extracorporeal circulation depend on local perfusion. A core temperature of 24 °C-25 °C is aimed at to extend ischemic tolerance of tissues. Information on cerebral perfusion and temperature is important for the safety of patients, but hardly accessible to measurement. A combined simulation model of hemodynamics and temperature is presented in this paper. The hemodynamics model employs the transmission-line approach and integrates the Circle of Willis (CoW). This allows for parameterization of individual aberrations. Simulation results of cerebral perfusion are shown for two configurations of the CoW. The temperature model provides spatial information on temperature fields. It considers heat transfer in the various tissues retrieving data of local tissue perfusion from the hemodynamics model. The combined model is evaluated by retrospective simulation of two aortic operations.Keywords
This publication has 37 references indexed in Scilit:
- Modeling and simulation of the cardiovascular system: a review of applications, methods, and potentials / Modellierung und Simulation des Herz-Kreislauf-Systems: ein Überblick zu Anwendungen, Methoden und PerspektivenBiomedical Engineering / Biomedizinische Technik, 2009
- 3D blood flow characteristics in the carotid artery bifurcation assessed by flow‐sensitive 4D MRI at 3TMagnetic Resonance in Medicine, 2008
- Visualization of iliac and proximal femoral artery hemodynamics using time‐resolved 3D phase contrast MRI at 3TJournal of Magnetic Resonance Imaging, 2007
- Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flowsJournal of Biomechanics, 2007
- 3D models of blood flow in the cerebral vasculatureJournal of Biomechanics, 2006
- Investigations of flow and pressure distributions in physical model of the circle of WillisJournal of Biomechanics, 2005
- Specific absorption rate and temperature elevation in a subject exposed in the far-field of radio-frequency sources operating in the 10-900-MHz rangeIEEE Transactions on Biomedical Engineering, 2003
- Thermoregulatory Vasoconstriction Impairs Active Core CoolingAnesthesiology, 1995
- A mathematical model of the flow in the circle of WillisJournal of Biomechanics, 1986
- A mathematical model of the flow in the posterior communicating arteriesJournal of Biomechanics, 1982