Difficult intubation in pregnancy
Author:
- 1 June 2011
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Anaesthesiology
- Vol. 24 (3) , 249-254
Abstract
This review focuses on difficult intubation in pregnant patients, particularly during the late pregnancy when physiological, patho-physiological and psychological factors may cause or aggravate difficulties with providing sufficient oxygenation and securing the airway. It is intended to highlight the methodological approach to the difficult airway in this particular patient population and to draw relevant principles in dealing with this problem. There are strong indications for improvement in the outcome of airway management in pregnant patients; however, this is obscured by the growing frequency of caesarean sections and connected to this by more tracheal intubations. Various new airway devices have been suggested as alternative techniques for laryngoscopic intubation if the latter becomes difficult or failed. A scenario-oriented approach to the problem of difficult intubation in pregnant patients leads to the recognition of the unpredicted difficult or failed intubation as the main concern. The appropriate means to cope with this rare but life-threatening complication lies in a gradual employment of principles beginning with preferential application of regional anaesthesia techniques, followed by proceeding according to locally adapted simple and comprehensive failed intubation algorithms, design of a suitable difficult airway cart that contains only a few but well chosen items and by implementation of a continuous and mandatory training program to which all personnel are subjected to participate in regular intervals.Keywords
This publication has 27 references indexed in Scilit:
- Comparison of the C‐MAC ® videolaryngoscope with the Macintosh, Glidescope ® , and Airtraq ® laryngoscopes in easy and difficult laryngoscopy scenarios in manikinsAnaesthesia, 2010
- The C-MAC Videolaryngoscope: First Experiences with a New Device for Videolaryngoscopy-Guided IntubationAnesthesia & Analgesia, 2010
- Difficult and failed intubation in 3430 obstetric general anaesthetics*Anaesthesia, 2009
- Comparison of the Glidescope®, the Pentax AWS®, and the Truview EVO2® with the Macintosh laryngoscope in experienced anaesthetists: a manikin studyBritish Journal of Anaesthesia, 2009
- Management of the difficult and failed airway in obstetric anesthesiaJournal of Anesthesia, 2008
- Ease of use of the airway scope vs the bullard laryngoscope: A manikin studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- Is regional anaesthesia better than general anaesthesia for caesarean section?Journal of Obstetrics and Gynaecology, 2006
- Comparison of preoperative gastric contents and serum gastrin concentrations in pregnant and nonpregnant womenJournal of Clinical Anesthesia, 2005
- Algorithms for management of the difficult airwayCurrent Opinion in Anaesthesiology, 2004
- Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy*Anaesthesia, 2004