The Feasibility of a Smart Surgical Probe for Verification of IRE Treatments Using Electrical Impedance Spectroscopy
Open Access
- 4 June 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (11) , 2674-2684
Abstract
Significance: Irreversible electroporation (IRE) is gaining popularity as a focal ablation modality for the treatment of unresectable tumors. One clinical limitation of IRE is the absence of methods for real-time treatment evaluation, namely actively monitoring the dimensions of the induced lesion. This information is critical to ensure a complete treatment and minimize collateral damage to the surrounding healthy tissue. Goal: In this study, we are taking advantage of the biophysical properties of living tissues to address this critical demand. Methods: Using advanced microfabrication techniques, we have developed an electrical impedance microsensor to collect impedance data along the length of a bipolar IRE probe for treatment verification. For probe characterization and interpretation of the readings, we used potato tuber, which is a suitable platform for IRE experiments without having the complexities of in vivo or ex vivo models. We used the impedance spectra, along with an electrical model of the tissue, to obtain critical parameters such as the conductivity of the tissue before, during, and after completion of treatment. To validate our results, we used a finite element model to simulate the electric field distribution during treatments in each potato. Results: It is shown that electrical impedance spectroscopy could be used as a technique for treatment verification, and when combined with appropriate FEM modeling can determine the lesion dimensions. Conclusions: This technique has the potential to be readily translated for use with other ablation modalities already being used in clinical settings for the treatment of malignancies.Keywords
Funding Information
- National Science Foundation (IIP-1026421)
- Virginia Center for Innovative Technology (MF13-034-LS)
- Institute for Critical Technology and Applied Science of Virginia Tech
This publication has 64 references indexed in Scilit:
- Impedance analysis of adherent cells after in situ electroporation: Non-invasive monitoring during intracellular manipulationsBiosensors and Bioelectronics, 2011
- A Parametric Study Delineating Irreversible Electroporation from Thermal Damage Based on a Minimally Invasive Intracranial ProcedureBioMedical Engineering OnLine, 2011
- The influence of skeletal muscle anisotropy on electroporation: in vivo study and numerical modelingMedical & Biological Engineering & Computing, 2010
- Electrical Field and Temperature Model of Nonthermal Irreversible Electroporation in Heterogeneous TissuesJournal of Biomechanical Engineering, 2009
- Temperature considerations during irreversible electroporationInternational Journal of Heat and Mass Transfer, 2008
- Tumor Ablation with Irreversible ElectroporationPLOS ONE, 2007
- Tissue Ablation with Irreversible ElectroporationAnnals of Biomedical Engineering, 2005
- A 32-site neural recording probe fabricated by DRIE of SOI substratesJournal of Micromechanics and Microengineering, 2002
- Determination of Coating Deterioration with EISCorrosion, 1991
- Electrochemotherapy potentiation of antitumour effect of bleomycin by local electric pulsesEuropean Journal of Cancer and Clinical Oncology, 1991