Three‐dimensional simultaneous brain T1, T2, and ADC mapping with MR Multitasking
- 25 November 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 72-88
Abstract
Purpose: To develop a simultaneous T1, T2, and ADC mapping method that provides co‐registered, distortion‐free images and enables multiparametric quantification of 3D brain coverage in a clinically feasible scan time with the MR Multitasking framework.Methods: The T1/T2/diffusion weighting was generated by a series of T2 preparations and diffusion preparations. The underlying multidimensional image containing 3 spatial dimensions, 1 T1 weighting dimension, 1 T2‐preparation duration dimension, 1 b‐value dimension, and 1 diffusion direction dimension was modeled as a 5‐way low‐rank tensor. A separate real‐time low‐rank model incorporating time‐resolved phase correction was also used to compensate for both inter‐shot and intra‐shot phase inconsistency induced by physiological motion. The proposed method was validated on both phantom and 16 healthy subjects. The quantification of T1/T2/ADC was evaluated for each case. Three post‐surgery brain tumor patients were scanned for demonstration of clinical feasibility.Results: Multitasking T1/T2/ADC maps were perfectly co‐registered and free from image distortion. Phantom studies showed substantial quantitative agreement () with reference protocols for T1/T2/ADC. In vivo studies showed nonsignificant T1 (P = .248), T2 (P = .97), ADC (P = .328) differences among the frontal, parietal, and occipital regions. Although Multitasking showed significant differences of T1 (P = .03), T2 (P < .001), and ADC (P = .001) biases against the references, the mean bias estimates were small (ΔT1% < 5%, ΔT2% < 7%, ΔADC% < 5%), with all intraclass correlation coefficients greater than 0.82 indicating “excellent” agreement. Patient studies showed that Multitasking T1/T2/ADC maps were consistent with the clinical qualitative images.Conclusion: The Multitasking approach simultaneously quantifies T1/T2/ADC with substantial agreement with the references and is promising for clinical applications.Keywords
Funding Information
- National Institutes of Health (R01 EB028146)
This publication has 64 references indexed in Scilit:
- High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 TMagnetic Resonance in Medicine, 2012
- Improved Detection of Myocardial Involvement in Acute Inflammatory Cardiomyopathies Using T2 MappingCirculation: Cardiovascular Imaging, 2012
- T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensingMagnetic Resonance in Medicine, 2011
- Neoadjuvant chemotherapy in breast cancer-response evaluation and prediction of response to treatment using dynamic contrast-enhanced and diffusion-weighted MR imagingEuropean Radiology, 2010
- Longitudinal study of the assessment by MRI and diffusion‐weighted imaging of tumor response in patients with locally advanced breast cancer undergoing neoadjuvant chemotherapyNMR in Biomedicine, 2008
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imagingMagnetic Resonance in Medicine, 2004
- Nonlinear phase correction for navigated diffusion imagingMagnetic Resonance in Medicine, 2003
- Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady stateMagnetic Resonance in Medicine, 2003
- A new T2 preparation technique for ultrafast gradient‐echo sequenceMagnetic Resonance in Medicine, 1994