Comparison of Using Second-Generation Cryoballoon and Radiofrequency Catheter for Atrial Fibrillation Ablation in Patients With the Common Ostium of Inferior Pulmonary Veins
Authors:
Open Access
- 11 January 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8, 794834
Abstract
Aims: To compare the procedural outcomes of cryoballoon ablation (CBA) and radiofrequency ablation (RFA) in atrial fibrillation (AF) patients with the common ostium of inferior pulmonary veins (COIPV) and to explore the effect of COIPV on CBA performance through the assessment of anatomical factors.Methods: A total of 18 AF patients with COIPV were included. Pulmonary vein isolation (PVI) was performed with second-generation CBA or RFA. The anatomical characteristics of COIPV and procedural outcomes were collected.Results: The prevalence of COIPV was 0.82% in the enrolled population. PVI was achieved in all pulmonary veins (PVs) without any complications. The “tricircle” strategy was applied for RFA, and the segmental freeze strategy was performed for CBA. Compared with RFA, CBA had shorter procedural time (median: 53.0 vs. 78.0 min, p < 0.001) and longer fluoroscopy time (median: 13.5 vs. 6.0 min, p < 0.001). Higher ovality index of the ostium was seen in patients with ≥4 freezes in inferior PVs [IPVs; 0.95 (0.78–1.05) vs. 0.49 (0.21–0.83), p = 0.047]. During a median of 23.5 months of follow-up, the atrial arrhythmias-free survival after the procedure was comparable between CBA and RFA (p = 0.729).Conclusion: The second-generation CBA is an efficient and safe alternative for RFA in AF patients with COIPV. Anatomical characteristics of COIPV bring the challenge to the procedure performance of RFA and CBA.Keywords
Funding Information
- National Natural Science Foundation of China (81670309)
This publication has 20 references indexed in Scilit:
- Best practice guide for cryoballoon ablation in atrial fibrillation: The compilation experience of more than 3000 proceduresHeart Rhythm, 2015
- The Clinical Profile and Pathophysiology of Atrial FibrillationCirculation Research, 2014
- Entire posterior wall isolation in an unusual case of common ostium between the right inferior and left inferior pulmonary veinsEP Europace, 2013
- Cryoballoon in AF ablation: Impact of PV ovality on AF recurrenceInternational Journal of Cardiology, 2013
- The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre studyEuropean Heart Journal, 2008
- Characteristics in Image Integration System Guiding Catheter Ablation of Atrial Fibrillation with a Common Ostium of Inferior Pulmonary VeinsPacing and Clinical Electrophysiology, 2007
- Esophageal Temperature Monitoring During Radiofrequency Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2005
- Complete Isolation of Left Atrium Surrounding the Pulmonary VeinsCirculation, 2004
- Variations in Pulmonary Venous Drainage to the Left Atrium: Implications for Radiofrequency AblationRadiology, 2004
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsThe New England journal of medicine, 1998