BIOMECHANICS OF BONE BLOCK GRAFT MODELS OF DIFFERENT GEOMETRY
Open Access
- 1 June 2019
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 27 (3) , 136-140
Abstract
Objective: To evaluate the mechanical behavior of different geometry bone block grafts in wooden models. Methods: Constructs with rectangular (G1) and trapezoidal (G2) profile “grafts”, fixed with 3.5 mm 8-hole dynamic compression plates were submitted to non-destructive bending, with the load applied alternately on the same surface as that of the plate fixation (upper) and on the opposite surface (lower), and torsion tests. A 50 N maximum load for bending and a 5° maximum deformation for torsion were considered. Rigidity (N/mm) was recorded for the former and torque (N.m) was recorded for the latter. Results: Rigidity was consistently higher in G2 than in G1, but not significantly so for all comparisons. The exception was for the load applied on the same surface of plate fixation, significantly higher in G1 than in G2. Torque was higher in G1, but not significantly so. Conclusion: The two different-profile “grafts” present a similar mechanical behavior and can be indistinctly used in clinical practice. Level of evidence V, specialist's opinion based on basic studies.Keywords
This publication has 10 references indexed in Scilit:
- Treatment of diaphyseal forearm atrophic nonunions with intramedullary nails and modified Nicoll’s technique in adultsActa Orthopaedica et Traumatologica Turcica, 2014
- The Effect of Repetitive Pilot-Hole Use on the Insertion Torque and Pullout Strength of Vertebral System ScrewsSpine, 2009
- Modification of the Nicoll bone-grafting technique for nonunion of the radius and/or ulnaThe Journal of Bone and Joint Surgery. British volume, 2002
- The influence of screw omission on construction stiffness and bone surface strain in the application of bone plates to cadaveric boneInjury, 1999
- The Strength of Plate Fixation in Relation to the Number and Spacing of Bone ScrewsJournal of Orthopaedic Trauma, 1996
- MANAGEMENT OF SEGMENTAL DEFECTS OF THE RADIUS AND ULNA1971
- THE TREATMENT OF GAPS IN LONG BONES BY CANCELLOUS INSERT GRAFTSThe Journal of Bone and Joint Surgery. British volume, 1956
- BRIDGING OF BONE DEFECTS IN THE FOREARM WITH ILIAC GRAFT COMBINED WITH INTRAMEDULLARY NAILINGThe Journal of Bone and Joint Surgery. British volume, 1954
- RESTORATION OF LONG BONE DEFECTS WITH MASSIVE BONE GRAFTSJAMA, 1948
- THE BRIDGING OF BONE DEFECTSJournal of Bone and Joint Surgery, 1948