Preventing Complications in Colorectal Anastomosis
Authors:
- Jose M. Enríquez-NavascuésJEJose M. Enríquez-Navascués
- Garazi ElorzaGEGarazi Elorza
- Ander TimoteoATAnder Timoteo
- Jose A. MugicaJMJose A. Mugica
- Nerea BordaNBNerea Borda
- Yolanda SaraleguiYSYolanda Saralegui
- Jose L. ElóseguiJEJose L. Elósegui
- 1 October 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 57 (10) , 1195-1201
Abstract
Anastomotic complications, including leaks, stenoses, and bleeding, cause considerable mortality and morbidity after colorectal surgery. The purpose of this work was to evaluate the effectiveness of bioabsorbable staple line reinforcement in reducing colorectal anastomotic complications. This was a prospective randomized clinical study. This study was conducted at a university hospital within a specialized colorectal unit. Patients undergoing left colon resection for a benign or malignant condition were eligible. A total of 302 patients participated, including 154 control subjects and 148 with reinforcement. Patients were prospectively randomly assigned to reinforcement of circular stapled anastomosis with a bioabsorbable device versus stapled circular anastomosis without reinforcement. The primary end point was the rate of pooled incidences of anastomotic complications (leakage, bleeding, or stenosis). Secondary outcomes were the rate of reoperations and the length of hospital stay. Baseline characteristics were similar between both groups. Intention-to-treat analysis revealed that there were no significant differences in the pooled incidences of anastomotic complications (p = 0.821). Regarding individual complications, we did not observe statistical differences between groups, including leakage (6.6% vs 4.8%; p = 0.518), hemorrhage (1.4% vs 1.3%; p = 0.431), or stenosis (2.9% vs 6.8%; p = 0.128). Again, no significant differences were observed in length of stay (7 days; p = 0.242) or rate of reoperation (7.3% vs 9.6%; p = 0.490). A patient (0.3%) in the control group died. Sample size calculation was performed including all 3 of the complications, which may render it underpowered to detect differences regarding a specific complication. Anastomoses located within 5 cm from the anal verge were excluded from the study. The results obtained show that bioabsorbable staple line reinforcement in a colorectal anastomosis >5 cm from the anal verge does not reduce the rate of pooled anastomotic complications (ie, leaks, bleeding, or stenosis).Keywords
This publication has 12 references indexed in Scilit:
- Bioabsorbable Staple Line Reinforcement in Restorative Proctectomy and Anterior ResectionDiseases of the Colon & Rectum, 2014
- Clinical Results Using Bioabsorbable Staple-Line Reinforcement for Circular Stapler in Colorectal Surgery: A Multicenter StudyJournal of Laparoendoscopic & Advanced Surgical Techniques, 2010
- Estenosis anastomóticas benignas en la cirugía radical del cáncer de recto. Resultados del tratamiento con dilatación hidrostáticaCirugía Española, 2010
- Complications in colorectal surgery: risk factors and preventive strategiesPatient Safety in Surgery, 2010
- Definition and grading of anastomotic leakage following anterior resection of the rectum: A proposal by the International Study Group of Rectal CancerSurgery, 2010
- Management of lower gastrointestinal bleeding after colorectal resection and stapled anastomosisTechniques in Coloproctology, 2009
- Colonic Anastomotic Leak: Risk Factors, Diagnosis, and TreatmentJournal of the American College of Surgeons, 2009
- The Use of Bioabsorbable Staple Line Reinforcement for Circular Stapler (BSG ???Seamguard???) in Colorectal SurgerySurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2006
- Safety and Efficacy of the Use of Bioabsorbable Seamguard in Colorectal Surgery at the Texas Endosurgery InstituteSurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2005
- Systematic review of the definition and measurement of anastomotic leak after gastrointestinal surgeryBritish Journal of Surgery, 2001