IoT-Based Wireless System for Gait Kinetics Monitoring in Multi-Device Therapeutic Interventions
Authors:
Open Access
Abstract
This study presents an IoT-based gait analysis system employing insole pressure sensors to assess gait kinetics. The system integrates piezoresistive sensors within a left foot insole, with data acquisition managed using an ESP32 board that communicates via Wi-Fi through an MQTT IoT framework. In this initial protocol study, we conducted a comparative analysis using the Zeno system, supported by PKMAS as the gold standard, to explore the correlation and agreement of data obtained from the insole system. Four volunteers (two males and two females, aged 24–28, without gait disorders) participated by walking along a 10 m Zeno system path, equipped with pressure sensors, while wearing the insole system. Vertical ground reaction force (vGRF) data were collected over four gait cycles. The preliminary results indicated a strong positive correlation (r = 0.87) between the insole and the reference system measurements. A Bland–Altman analysis further demonstrated a mean difference of approximately (0.011) between the two systems, suggesting a minimal yet significant bias. These findings suggest that piezoresistive sensors may offer a promising and cost-effective solution for gait disorder assessment and monitoring. However, operational factors such as high temperatures and sensor placement within the footwear can introduce noise or unwanted signal activation. The communication framework proved functional and reliable during this protocol, with plans for future expansion to multi-device applications. It is important to note that additional validation studies with larger sample sizes are required to confirm the system’s reliability and robustness for clinical and research applications.Keywords
Funding Information
- CAPES (Coordination for the Improvement of Higher Education Personnel)
- CNPq (National Council for Scientific and Technological Development)
- MEC (Ministry of Education and Culture)
- Federal Institute of Education, Science, and Technology of Rio Grande do Norte
This publication has 44 references indexed in Scilit:
- Therapeutic Smart Insole Technology with Archimedean Algorithmic Spiral Triboelectric Nanogenerator-Based Power System and SensorsAdvanced Fiber Materials, 2024
- Carbon Fiber‐Based Smart Plantar Pressure Mapping Insole System for Remote Gait Analysis and Motion IdentificationAdvanced Materials Technologies, 2023
- Parkinson's diseaseThe Lancet, 2021
- A real IoT device deployment for e-Health applications under lightweight communication protocols, activity classifier and edge data filteringComputer Communications, 2018
- Reliability and validity of the protokinetics movement analysis software in measuring center of pressure during walkingGait & Posture, 2017
- Cerebral palsyThe Lancet, 2014
- The history of gait analysis before the advent of modern computersGait & Posture, 2007
- The evolution of clinical gait analysisGait & Posture, 2002
- The evolution of clinical gait analysis part l: kinesiological EMGGait & Posture, 2001
- The Nature of the Data, or How to Choose a Correlation CoefficientPsychometrika, 1961