An Artifact-Resistant Feature SKNAER for Quantifying the Burst of Skin Sympathetic Nerve Activity Signal
Open Access
- 20 May 2022
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 12 (5) , 355
Abstract
Evaluation of sympathetic nerve activity (SNA) using skin sympathetic nerve activity (SKNA) signal has attracted interest in recent studies. However, signal noises may obstruct the accurate location for the burst of SKNA, leading to the quantification error of the signal. In this study, we use the Teager–Kaiser energy (TKE) operator to preprocess the SKNA signal, and then candidates of burst areas were segmented by an envelope-based method. Since the burst of SKNA can also be discriminated by the high-frequency component in QRS complexes of electrocardiogram (ECG), a strategy was designed to reject their influence. Finally, a feature of the SKNA energy ratio (SKNAER) was proposed for quantifying the SKNA. The method was verified by both sympathetic nerve stimulation and hemodialysis experiments compared with traditional heart rate variability (HRV) and a recently developed integral skin sympathetic nerve activity (iSKNA) method. The results showed that SKNAER correlated well with HRV features (r = 0.60 with the standard deviation of NN intervals, 0.67 with low frequency/high frequency, 0.47 with very low frequency) and the average of iSKNA (r = 0.67). SKNAER improved the detection accuracy for the burst of SKNA, with 98.2% for detection rate and 91.9% for precision, inducing increases of 3.7% and 29.1% compared with iSKNA (detection rate: 94.5% (p < 0.01), precision: 62.8% (p < 0.001)). The results from the hemodialysis experiment showed that SKNAER had more significant differences than aSKNA in the long-term SNA evaluation (p < 0.001 vs. p = 0.07 in the fourth period, p < 0.01 vs. p = 0.11 in the sixth period). The newly developed feature may play an important role in continuously monitoring SNA and keeping potential for further clinical tests.Keywords
Funding Information
- National Key Research and Development Program of China (2019YFE0113800, 62171123, 81871444, 62001111, 62071241, BK20190014, BK20192004, BK20200364)
- The National Natural Science Foundation of China (2019YFE0113800, 62171123, 81871444, 62001111, 62071241, BK20190014, BK20192004, BK20200364)
- the Natural Science Foundation of Jiangsu Province of China (2019YFE0113800, 62171123, 81871444, 62001111, 62071241, BK20190014, BK20192004, BK20200364)
This publication has 39 references indexed in Scilit:
- Characterization of textile electrodes and conductors using standardized measurement setupsPhysiological Measurement, 2010
- Preventing Heart Disease in the 21st CenturyCirculation, 2008
- Supine low-frequency power of heart rate variability reflects baroreflex function, not cardiac sympathetic innervationHeart Rhythm, 2007
- Circadian variations of stellate ganglion nerve activity in ambulatory dogsHeart Rhythm, 2006
- Diabetic Autonomic NeuropathyDiabetes Care, 2003
- Analysis of raw microneurographic recordings based on wavelet de-noising technique and classification algorithm: wavelet analysis in microneurographyIEEE Transactions on Biomedical Engineering, 2003
- A new method of quantifying human muscle sympathetic nerve activity for frequency domain analysisElectroencephalography and Clinical Neurophysiology/Electromyography and Motor Control, 1996
- Effects of the cold pressor test on muscle sympathetic nerve activity in humans.Hypertension, 1987
- Pulse and Respiratory Grouping of Sympathetic Impulses in Human Muscle NervesActa Physiologica Scandinavica, 1968
- A simple test of cardiac function based upon the heart rate changes induced by the valsalva maneuverThe American Journal of Cardiology, 1966