Prediction of moisture present in cellulosic part of power transformer insulation using transfer function of modified debye model
Authors:
- 16 June 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (3) , 1368-1375
Abstract
Polarization-Depolarization Current (PDC) analysis is a well known technique for condition monitoring of oil-paper insulation in power transformers. However, due to variation in insulation geometry, information obtained through analysis of PDC measured for one transformer cannot be used for predicting condition of another transformer even if the loading history of the two units are similar. Furthermore, parts of solid insulation closer to winding are exposed to much higher temperature than the parts away from it. Prolonged exposure to this temperature variation leads to nonuniform aging in cellulosic parts. It is reported that Modified Debye Model (MDM) is capable of modeling this non-uniform aging. In the present work it is shown that a parameter sensitive to insulation condition can be obtained from Transfer Function of MDM. Several laboratory samples having different physical dimensions has been constructed. PDC data recorded from these samples are used to obtain the performance parameter (which is less influenced by insulation geometry) and its relation to paper moisture content. The results obtained from the proposed method have been compared with that obtained using Frequency Domain Spectroscopy (FDS) based commercial instrument (IDAX 300) in the case of real-life power transformer.Keywords
This publication has 16 references indexed in Scilit:
- Assessment of non-uniform aging of solid dielectric using system poles of a modified debye model for oil-paper insulation of transformersIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- On the Feasibility of Using Poles Computed from Frequency Domain Spectroscopy to Assess Oil Impregnated Paper Insulation ConditionsEnergies, 2013
- On the frequency domain dielectric response of oil-paper insulation at low temperaturesIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Dielectric response of mineral oil impregnated cellulose and the impact of agingIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- PDC measurement evaluation on oil-pressboard samples2004
- Dielectric spectroscopy in time and frequency domain for HV power equipment. I. Theoretical considerationsIEEE Electrical Insulation Magazine, 2003
- Time domain measurements of dielectric response in oil-paper insulation systems2002
- On-site diagnosis of power transformers by means of relaxation current measurements2002
- Application of relaxation current measurements to on-site diagnosis of power transformers2002
- Determination of moisture content in mass impregnated cable insulation using low frequency dielectric spectroscopy2002