Taperosis
- 1 July 2015
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 97-B (7) , 911-916
Abstract
Tribocorrosion at the head–neck taper interface – so-called ‘taperosis’ – may be a source of metal ions and particulate debris in metal-on-polyethylene total hip arthroplasty (THA). We examined the effect of femoral head length on fretting and corrosion in retrieved head–neck tapers in vivo for a minimum of two years (mean 8.7 years; 2.6 to 15.9). A total of 56 femoral heads ranging from 28 mm to 3 mm to 28 mm + 8 mm, and 17 femoral stems featuring a single taper design were included in the study. Fretting and corrosion were scored in three horizontally oriented concentric zones of each taper by stereomicroscopy. Head length was observed to affect fretting (p = 0.03), with 28 mm + 8 mm femoral heads showing greater total fretting scores than all other head lengths. The central zone of the femoral head bore taper was subject to increased fretting damage (p = 0.01), regardless of head length or stem offset. High-offset femoral stems were associated with greater total fretting of the bore taper (p = 0.04). Increased fretting damage is seen with longer head lengths and high-offset femoral stems, and occurs within a central concentric zone of the femoral head bore taper. Further investigation is required to determine the effect of increased head size, and variations in head–neck taper design. Cite this article: Bone Joint J 2015; 97-B:911–16.Keywords
This publication has 15 references indexed in Scilit:
- The immunobiology of cobaltThe Bone & Joint Journal, 2014
- Raised levels of metal ions in the blood in patients who have undergone uncemented metal-on-polyethylene Trident–Accolade total hip replacementThe Bone & Joint Journal, 2014
- Femoral taperosisThe Bone & Joint Journal, 2013
- The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip JointsThe Journal of Arthroplasty, 2013
- A Comparison of Two Implant Systems in Restoration of Hip Geometry in ArthroplastyClinical Orthopaedics and Related Research, 2011
- A retrospective comparative study of mortality and causes of death among patients with metal-on-metal and metal-on-polyethylene total hip prostheses in primary osteoarthritis after a long-term follow-upBMC Musculoskeletal Disorders, 2010
- The John Charnley Award: Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- Metal-on-Metal Versus Polyethylene in Hip Arthroplasty: A Randomized Clinical TrialClinical Orthopaedics and Related Research, 2003
- A Multicenter Retrieval Study of the Taper Interfaces of Modular Hip ProsthesesClinical Orthopaedics and Related Research, 2002
- In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy couplingJournal of Biomedical Materials Research, 1993