Investigation of Damping Effect of PLL on Low-Frequency Harmonic Stability of Grid-Tied Inverter With αβ and dq Current Control Schemes
- 12 May 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (1) , 1046-1060
Abstract
The choice of phase-locked loop (PLL) bandwidth in three-phase grid-tied inverters (GTIs) is always a tradeoff between robust performance under distorted grid conditions and fast detection of grid voltage phase angle during the low-voltage ride through. Besides, even though both the GTI with decoupled dq -frame (CC1) and ${\alpha \beta }$ -frame (CC2) current control schemes employ PLL for grid synchronization, and damping effect of PLL, which is a function of its control bandwidth, is not identical. As a consequence, the output impedance of GTI with CC1 and CC2 has diverse interaction scenarios with the weak grid impedance. Therefore, this work investigates the impact of PLL bandwidth on the output impedance of GTI in the two different current control schemes using impedance models in a common frame of reference ( dq -frame here). Negative damping region exhibited by ${q}$ -axis impedances are identified. It is found that CC2 has a less significant negative damping region, while that of CC1 widens with the increase in PLL bandwidth. Furthermore, the side effects of dissimilar damping regions on inverter-grid system stability are demonstrated through the impedance interaction analysis. The output impedance shaping caused by voltage feedforward and outer power control loops on CC1 and CC2 is also investigated. Finally, a compensator is designed to overcome the phase lag introduced by PLL and voltage feedforward loop. The above findings are validated through MATLAB/Simulink simulations and experiments.Keywords
Funding Information
- Department of Science and Technology (DST), India Smart Grid Research Initiatives under the Research Grants: US-India collAborative for smart diStribution System wIth STorage
- Indo-U.K. Collaboration for Zero Peak Energy Building Design for India
- Demonstration of MW-scale Solar Integration in weak grids using Distributed Energy Storage architecture
- Indo-Danish collaboration for data-driven control and optimization for a highly Efficient Distribution Grid
This publication has 32 references indexed in Scilit:
- Impedance-Phased Dynamic Control Method for Grid-Connected Inverters in a Weak GridIEEE Transactions on Power Electronics, 2016
- Influence of voltage feed-forward control on small-signal stability of grid-tied inverters2015
- Analysis of D-Q Small-Signal Impedance of Grid-Tied InvertersIEEE Transactions on Power Electronics, 2015
- Grid Harmonics Suppression Scheme for LCL-Type Grid-Connected Inverters Based on Output Admittance RevisionIEEE Transactions on Sustainable Energy, 2015
- Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC ConverterIEEE Transactions on Power Delivery, 2014
- Input impedance of voltage source converter with stationary frame linear current regulators and phase-locked loop2013
- $LCL$ Filter Design and Performance Analysis for Grid-Interconnected SystemsIEEE Transactions on Industry Applications, 2013
- Regions of Active Damping Control for LCL FiltersIEEE Transactions on Industry Applications, 2013
- Frequency-domain analysis of three-phase linear current regulatorsIEEE Transactions on Industry Applications, 2001
- A phase tracking system for three phase utility interface invertersIEEE Transactions on Power Electronics, 2000