Trace elements in normal and cirrhotic human liver tissue I. Iron, copper, zinc, selenium, manganese, titanium and lead measured by X‐ray fluorescence spectrometry

Authors:

Abstract
ABSTRACT— Trace elements (Fe, Cu, Zn, Se, Mn, Ti, Pb) were measured by X‐ray fluorescence spectrometry in normal liver tissue obtained at autopsy from 74 subjects (44 ♀, 30 ♂), median age 62 years (range 20–87), and in tissue from 27 cirrhotic livers (14 alcoholic, 13 non‐alcoholic cirrhosis). The element content (median and 5–95 percentile interval) in normal livers in mmol/kg dry tissue was: Fe, 16.51 (7.82–39.03); Cu, 0.378 (0.189–0.629); Zn, 4.01 (2.59–9.33); Se, 0.018 (Mn, Ti, Pb, cirrhotic liver, Fe content was within normal, Cu content above normal (PSe content below normal (PZn levels (PMn levels (PPb levels (P<0.03) than normal livers.

This publication has 22 references indexed in Scilit: