Visual outcome comparison of unilateral versus bilateral implantation of apodized diffractive multifocal intraocular lenses after cataract extraction
Authors:
- Robert J. CionniRCRobert J. Cionni
- Robert H. OsherRORobert H. Osher
- Michael E. SnyderMSMichael E. Snyder
- Michael L. NordlundMNMichael L. Nordlund
- 1 June 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (6) , 1033-1039
Abstract
To evaluate the visual outcomes and patient satisfaction after unilateral implantation or stepwise bilateral implantation of an apodized diftractive multifocal intraocular lens (IOL). Private practice, Cincinnati, Ohio, USA. Patients requiring cataract surgery in 1 eye were recruited. AcrySof ReSTOR IOLs were implanted in 1 eye of patients with phakic contralateral eyes, patients with contralateral monofocal IOLs, and patients with a contralateral multifocal IOL of the same model. Six months postoperatively, patients were assessed for visual acuity (31.0 cm, 50.0 cm, 4.0 m), contrast sensitivity, and stereopsis. Patients were surveyed for visual disturbances and lifestyle visual quality. Of unilateral multifocal IOL patients, 75% were satisfied with their vision (score 7.3 out of 10) and a majority (56% multifocal-phakic, 65% multifocal-monofocal) achieved spectacle independence. These values were slightly lower than values for bilateral multifocal patients (92% satisfied, 77% spectacle independent), but not at a statistically significant level. Mean overall patient satisfaction was statistically significantly different: 8.9 for bilateral patients versus 7.3 for unilateral patients. Objectively, significant differences favored bilateral implantation over unilateral implantation for stereopsis, uncorrected near visual acuity, and best corrected near and intermediate visual acuities. Contrast sensitivity was similar between groups in most cases. The incidence of halos was lower in unilateral patients (57%) than in bilateral patients (77%), although the difference did not reach statistical significance. Although unilateral implantation of a multifocal IOL provided patients with high levels of spectacle freedom and good visual acuity without compromising contrast sensitivity, overall clinical results favored bilateral implantation.Keywords
This publication has 23 references indexed in Scilit:
- Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or youngerJournal of Cataract & Refractive Surgery, 2008
- Optical Performance Measurement and Night Driving Simulation of ReSTOR, ReZoom, and Tecnis Multifocal Intraocular Lenses in a Model EyeJournal of Refractive Surgery, 2008
- Visualization of the Retinal Image in an Eye Model With Spherical and Aspheric, Diffractive, and Refractive Multifocal Intraocular LensesJournal of Refractive Surgery, 2008
- Image quality with multifocal intraocular lenses and the effect of pupil sizeJournal of Cataract & Refractive Surgery, 2007
- Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- A comparison of patient-reported outcomes from an apodized diffractive intraocular lens and a conventional monofocal intraocular lensCurrent Medical Research and Opinion, 2006
- Visual performance with multifocal intraocular lensesOphthalmology, 2004
- Multifocal versus monofocal intraocular lenses in cataract surgeryOphthalmology, 2003
- Halo size under distance and near conditions in refractive multifocal intraocular lensesBritish Journal of Ophthalmology, 2001
- Diffractive multifocal intraocular lens implants for unilateral cataracts in prepresbyopic patients.British Journal of Ophthalmology, 1992