Comparison of an IgG-Specific Enzyme-Linked Immunosorbent Assay Cutoff of 0.4 Versus 0.8 and 1.0 Optical Density Units for Heparin-Induced Thrombocytopenia
- 10 July 2016
- journal article
- research article
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 23 (3) , 282-286
Abstract
Background: Previous studies have demonstrated optimized diagnostic accuracy in utilizing higher antiheparin–platelet factor 4 (PF4) enzyme-linked immunosorbent assay (ELISA) optical density (OD) thresholds for diagnosing heparin-induced thrombocytopenia (HIT). We describe the incidence of positive serotonin release assay (SRA) results, as well as performance characteristics, for antiheparin–PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units in the diagnosis of HIT at our institution. Methods: Following institutional review board approval, we conducted a single-center retrospective chart review on adult inpatients with a differential diagnosis of HIT evaluated by both antiheparin–PF4 ELISA and SRA from 2012 to 2014. The major endpoints were to assess incidence of positive SRA results, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy at antiheparin–PF4 ELISA values ≥0.4 OD units when compared to values ≥0.8 and ≥1.0 OD units. Clinical characteristics, including demographics, laboratory values, clinical and safety outcomes, length of stay, and mortality, were collected. Results: A total of 140 patients with 140 antiheparin–PF4 ELISA and SRA values were evaluated, of which 23 patients were SRA positive (16.4%) and 117 patients were SRA negative (83.6%). We identified a sensitivity of 91.3% versus 82.6% and 73.9%, specificity of 61.5% versus 87.2% and 91.5%, PPV of 31.8% versus 55.9% and 63.0%, NPV of 97.3% versus 96.2% and 94.7%, and accuracy of 66.4% versus 86.4% and 88.6% at antiheparin–PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units, respectively. Conclusion: Our study suggests an increased antiheparin–PF4 ELISA threshold of 0.8 or 1.0 OD units enhances specificity, PPV, and accuracy while maintaining NPV with decreased sensitivity.Keywords
This publication has 8 references indexed in Scilit:
- The Role for Optical Density in Heparin-Induced ThrombocytopeniaChest, 2015
- Improving Clinical Interpretation of the Anti-Platelet Factor 4/Heparin Enzyme-Linked Immunosorbent Assay for the Diagnosis of Heparin-Induced Thrombocytopenia Through the Use of Receiver Operating Characteristic Analysis, Stratum-Specific Likelihood Ratios, and Bayes TheoremChest, 2013
- Impact of an Immunoglobulin G–Specific Enzyme‐Linked Immunosorbent Assay on the Management of Heparin‐Induced ThrombocytopeniaPharmacotherapy: The Journal of Human Pharmacology and Drug Therapy, 2013
- How I Diagnose and Manage HITHematology-American Society Hematology Education Program, 2011
- ASH evidence-based guidelines: is the IgG-specific anti-PF4/heparin ELISA superior to the polyspecific ELISA in the laboratory diagnosis of HIT?Hematology-American Society Hematology Education Program, 2009
- Quantitative interpretation of optical density measurements using PF4‐dependent enzyme‐immunoassaysJournal of Thrombosis and Haemostasis, 2008
- Evaluation of pretest clinical score (4 T's) for the diagnosis of heparin‐induced thrombocytopenia in two clinical settingsJournal of Thrombosis and Haemostasis, 2006
- New Approaches to the Diagnosis of Heparin-Induced ThrombocytopeniaChest, 2005