OCT-Derived Plaque Morphology and FFR-Determined Hemodynamic Relevance in Intermediate Coronary Stenoses
Authors:
- Mariusz TomaniakMariusz Tomaniak
- Dorota OchijewiczDODorota Ochijewicz
- Łukasz KołtowskiŁKŁukasz Kołtowski
- Adam RdzanekARAdam Rdzanek
- Arkadiusz PietrasikAPArkadiusz Pietrasik
- Jacek JąkałaJJJacek Jąkała
- Magdalena SlezakMSMagdalena Slezak
- Krzysztof P. MalinowskiKMKrzysztof P. Malinowski
- Martyna ZaleskaMZMartyna Zaleska
- Jakub MaksymJMJakub Maksym
- Piotr BarusPBPiotr Barus
- Tomasz RolederTRTomasz Roleder
Open Access
- 28 May 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (11) , 2379
Abstract
Background: optical coherence tomography (OCT) might allow identifying lesion features reportedly associated with plaque vulnerability and increased risk of clinical events. Previous studies on correlation between OCT and functional lesion significance indices reported contradictory results, yet integration of complementary information from both modalities is gaining increased interest. The aim of the study was to compare plaque morphology using OCT in hemodynamically relevant vs. non-relevant lesions by fractional flow reserve (FFR). Methods: consecutive patients with intermediate grade coronary stenoses by angiography were evaluated by both FFR and OCT in this single-center study. Stenoses were labeled hemodynamically relevant in case of the FFR ≤ 0.80. Minimal lumen area (MLA), fibrous cap thickness (FCT), minimal cap thickness over the calcium, angle of the calcium, and necrotic core within the lesions were evaluated. Results: a total of 105 patients (124 vessels) were analyzed. Of them, 65 patients were identified with at least one lesion identified as hemodynamically relevant by FFR (72 vessels, 58.1%). Lesions with FFR ≤0.80 presented with lower mean and minimal lumen area (3.46 ± 1.29 vs. 4.65 ± 2.19, p =0.001 and 1.84 ± 0.97 vs. 2.66 ± 1.40, p = 0.001) compared to patients with FFR > 0.80. No differences were found between groups in the mean and minimal FCT, mean, and maximal necrotic core, calcium angle, as well as the overall rate of calcified and lipid plaques. Conclusion: hemodynamic relevance of intermediate grade lesions correlated moderately with the luminal assessment by OCT. No differences were identified in the plaque morphology between relevant and non-relevant coronary stenoses by FFR.Keywords
This publication has 40 references indexed in Scilit:
- Relationship between optical coherence tomography derived intraluminal and intramural criteria and haemodynamic relevance as determined by fractional flow reserve in intermediate coronary stenoses of patients with type 2 diabetesHeart, 2013
- FIRST: Fractional Flow Reserve and Intravascular Ultrasound Relationship StudyJACC, 2013
- Visual-Functional Mismatch Between Coronary Angiography and Fractional Flow ReserveJACC: Cardiovascular Interventions, 2012
- Expert review document part 2: methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional proceduresEuropean Heart Journal, 2012
- Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography StudiesJACC, 2012
- Morphometric Assessment of Coronary Stenosis Relevance With Optical Coherence TomographyJACC, 2012
- Fractional Flow Reserve Versus Angiography for Guiding Percutaneous Coronary Intervention in Patients With Multivessel Coronary Artery DiseaseJACC, 2010
- Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosisEuropean Heart Journal, 2009
- Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary InterventionThe New England journal of medicine, 2009
- In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence TomographyCirculation, 2005