Surgical comfort and clinical outcomes of MIPO with an extra-short plate designed for distal radius fractures
- 21 September 2020
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 31 (3) , 481-490
Abstract
Objectives Volar locking plates (VLPs) are increasingly used for distal radius fractures (DRFs) with minimally invasive plate osteosynthesis (MIPO), but surgery learning curves could be long. The purpose of this study was to assess a new extra-short plate with two locking diaphyseal divergent screws, specifically designed for MIPO, preserving the pronator quadratus muscle. Materials and methods This retrospective study consisted of three phases: (i) the evaluation of surgical comfort with the incision size and the duration of 59 consecutive surgeries using the extra-short plate in DRFs; (ii) the verification of the implant ability to maintain radiographic indices compared immediately postoperatively and at consolidation. They included radial inclination (RI), volar tilt (VT) and ulnar variance (UV); (iii) the assessment of clinical outcomes at last follow-up through: pain measured on the visual analogue scale (VAS), QuickDASH score, patient-rated wrist evaluation (PRWE) score, grip strength, range of motion and complications. Results In the first phase: mean incision size was 32 mm, and mean operative time was 28.5 min. In the second phase, there was no statistical difference between the two measures of the indices studied. In the third phase, mean follow-up time was 14.2 months, VAS score was 1.1, QuickDASH score was 11.4/100, and PRWE score was 9.5/100. Flexion was 91%, extension was 94%, and grip strength was 86% compared to the contralateral side. Conclusion The surgical comfort may be related to short operative time and incision. The implant allowed maintaining the radiographic indices without secondary displacement. Functional clinical outcomes were satisfactory. This extra-short plate design belongs to a novel generation of VLPs.Keywords
This publication has 31 references indexed in Scilit:
- Pronator-Sparing Technique for Volar Plating of Distal Radius FracturesThe Journal of Hand Surgery, 2014
- Technical note: How to spare the pronator quadratus during MIPO of distal radius fractures by using a mini-volar plateChirurgie de la Main, 2014
- Distal radius fixation through a mini-invasive approach of 15 mm. PART 1: a series of 144 casesEuropean Journal of Orthopaedic Surgery & Traumatology, 2013
- Distal radius fixation through a mini-invasive approach of 15 mm. Part 1: feasibility studyEuropean Journal of Orthopaedic Surgery & Traumatology, 2013
- Fixation of distal radius fractures in adults: A reviewOrthopaedics & Traumatology: Surgery & Research, 2013
- Minimally invasive plate osteosynthesis for distal radius fractures with a palmar locking plateEuropean Journal of Trauma and Emergency Surgery, 2012
- Clinical Results of Volar Locking Plate for Distal Radius Fractures: Conventional versus Minimally Invasive Plate OsteosynthesisJournal of Orthopaedic Trauma, 2011
- Volar Locking Plate Implant Prominence and Flexor Tendon RuptureJournal of Bone and Joint Surgery, 2011
- Percutaneous Pins Versus Volar Plates for Unstable Distal Radius Fractures: A Biomechanic Study Using a Cadaver ModelThe Journal of Hand Surgery, 2007
- Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adultsJournal of Orthopaedic Research, 2004