A new approach to the analysis of thermoluminescence glow-curve of TLD-600 dosimeters following Am-241 alpha particles irradiation
Authors:
- 1 February 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 178 (3) , 260-271
Abstract
A new approach to the analysis of thermoluminescence (TL) glow-curves of LiF:Mg, Ti (TLD-600) following alpha particles irradiation has been presented using general expressions derived from the one-trap-one recombination (OTOR)-level model. It has been found that the results of the deconvolution in the case of using these expressions are different from the case of using the other TL expressions, especially for the high-temperature region. The advantage of using the OTOR expressions is that, unlike the usual analysis, a good fit and reasonable kinetic parameter values could be obtained with a lower number of deconvoluted peaks. The kinetic parameters and the dosimetric properties of each peak have been investigated over different absorbed doses and new findings have been found. Improvement of the accuracy and the precision of the dose measurements at low-dose levels has been achieved using the glow-curve deconvolution algorithm. In addition, theoretical interpretations of some observed behaviors have been presented using the interactive multiple trap system model.Keywords
This publication has 43 references indexed in Scilit:
- Mysteries of LiF TLD response following high ionisation density irradiation: nanodosimetry and track structure theory, dose response and glow curve shapesRadiation Protection Dosimetry, 2010
- The thermoluminescence dose response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)Radiation Protection Dosimetry, 2007
- TL response of LiF : Mg,Ti exposed to intermediate energy1H,3He,12C,16O and20Ne ionsJournal of Physics D: Applied Physics, 2007
- Study of the energy deposition in LiF by heavy charged particle irradiation and its relation to the thermoluminescent efficiency of the materialJournal of Physics D: Applied Physics, 1999
- Analysis of Peak V of LiF TLD-100 by Curve FittingPhysica Status Solidi (a), 1993
- A microdosimetric track interaction model applied to alpha-particle-induced supralinearity and linearity in thermoluminescent LiF:Mg, TiJournal of Physics D: Applied Physics, 1988
- Response curves for the thermoluminescence induced by alpha particles: interpretation using track structure theoryPhysics in Medicine & Biology, 1982
- Kinetics and trapping parameters of thermoluminescence in LiF TLD-100-dependence on doseJournal of Physics D: Applied Physics, 1979
- Figure-of-merit (FOM), an improved criterion over the normalized chi-squared test for assessing goodness-of-fit of gamma-ray spectral peaksNuclear Instruments and Methods, 1977
- Dose dependence of thermoluminescence peaksJournal of Physics D: Applied Physics, 1974