Albuterol delivery via metered dose inhaler in a spontaneously breathing pediatric tracheostomy model
Authors:
- 5 November 2012
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 48 (10) , 1026-1034
Abstract
Rationale Little data are available regarding efficiency of drug delivery devices and techniques despite their widespread use in spontaneously breathing tracheostomized patients. We compared patient dose achieved with different devices, inhalation techniques, tracheostomy tube sizes and breathing patterns using a spontaneously breathing tracheostomized pediatric model. Methods A tracheostomy model was connected in series to a breathing simulator with a filter interposed (patient dose). Breathing patterns of a 16‐month‐old and a 6‐ and 12‐year‐old child with tracheostomy with internal diameters (mm) of 3.5, 4.5, and 5.5 were used. Albuterol HFAp MDI was used. Aerotrach Plus, MediBag, Aerochamber MV, Aerochamber Mini, and inline adapter with 6‐inch tubing were tested. The latter 3 devices were also tested with assisted technique. Albuterol was analyzed via spectrophotometry. Results Aerotrach Plus outperformed almost all devices tested. Aerochamber MV with unassisted technique was the second best and the adapter was the worst. Comparison of efficiency between best and worst performer ranged from 3‐ to 17.2‐fold. The 16‐month‐old breathing pattern and the 3.5 mm tracheostomy tube had the lowest patient dose. The use of assisted technique decreased patient dose by 18–67% for the 4.5 and 5.5 mm but not for 3.5 mm tracheostomy tubes. A median of 7.4% of the nominal dose was deposited in the tracheostomy tubes. Conclusions Aerotrach Plus and the adapter were the most and least efficient devices respectively. Tracheostomy size and breathing pattern affected drug delivery. The use of assisted technique reduced aerosol delivery. Pediatr Pulmonol. 2013; 48:1026–1034.Keywords
Funding Information
- James H. Hamlen II Chair Funds
This publication has 27 references indexed in Scilit:
- Effect of face mask dead volume, respiratory rate, and tidal volume on inhaled albuterol deliveryPediatric Pulmonology, 2010
- Modification of a spacer device for paediatric tracheostomyClinical Otolaryngology, 2008
- Calculated Deposition in Growing Tracheobronchial Airways: Effect of Growth-Rate AssumptionsInhalation Toxicology, 2006
- Hydrofluoroalkane-beclomethasone versus chlorofluorocarbon-beclomethasone delivery in neonatal modelsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2004
- Administration of inhaled medication via a tracheostomy in infants with chronic lung disease of prematurityPediatric Rehabilitation, 1999
- The delivery of aerosolized steroids from MDIs with nozzle extensions: Quantitative laboratory evaluation of a method to improve aerosol delivery to intubated patientsIntensive Care Medicine, 1995
- Evaluation of techniques for delivery of steroids to lungs of neonates using a rabbit model.Archives of Disease in Childhood, 1992
- The delivery of therapeutic aerosols through endotracheal tubesPediatric Pulmonology, 1986
- The use of a conical spacer after laryngectomy.BMJ, 1984
- Design and characteristics of a portable breath actuated, particle size selective medical aerosol inhalerJournal of Aerosol Science, 1982