Comparison of Higher-Order Aberration and Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses
Open Access
- 1 January 2007
- journal article
- research article
- Published by Yonsei University College of Medicine in Yonsei Medical Journal
- Vol. 48 (4) , 627-33
Abstract
The visual performance of pseudophakic eyes depends on the type of intraocular lenses (IOLs) that are implanted. Aspherical and multifocal IOLs have recently been developed to improve visual quality after cataract surgery, but multifocal IOLs can be associated with decreased contrast sensitivity (CS), halos, and glare. This study compares the visual performance of monofocal and multifocal IOLs by measurement of higher-order aberrations (HOAs) and CS values. HOAs and CS values of 42 eyes with implanted monofocal IOLs and 40 eyes with implanted multifocal IOLs were measured preoperatively and more than 6 months after surgery. In the multifocal IOL group, HOAs and CS values were also measured with addition of a trial lens of -0.5 diopter (D) to evaluate the compensatory effect on spherical aberration. CS values of the multifocal IOL group were significantly lower than those of the monofocal IOL group for all spatial frequencies tested (p<0.01), and the spherical aberration was significantly higher in the multifocal IOL group than in the monofocal IOL group (p<0.001). Addition of a -0.5 D lens to the multifocal IOL group decreased the difference in CS between the two groups (p=0.003). Increased spherical aberration may contribute to lower CS in the multifocal IOL group. In such cases, CS can be improved by addition of a -0.5 D lens to compensate for the spherical aberration.Keywords
This publication has 17 references indexed in Scilit:
- Glare disability and spherical aberration with five foldable intraocular lenses: a prospective randomized studyActa Ophthalmologica Scandinavica, 2005
- Contrast Sensitivity Function of Sound Eye after Occlusion Therapy in the Amblyopic ChildrenYonsei Medical Journal, 2005
- Causes of spherical aberration induced by laser refractive surgeryJournal of Cataract & Refractive Surgery, 2005
- Characterization of visual phenomena with the Array multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2002
- Cataract extraction with multifocal intraocular lens implantationOphthalmology, 2000
- Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation11The authors have no commercial or financial interest in any aspect of this study.Ophthalmology, 1999
- A prospective comparative study of the amo array zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lensOphthalmology, 1999
- Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 1998
- Untersuchungen zur Blendempfindlichkeit phaker und pseudophaker AugenKlinische Monatsblätter für Augenheilkunde, 1996