Increasing the accuracy and temporal resolution of two-filter radon–222 measurements by correcting for the instrument response
Open Access
- 28 June 2016
- journal article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 9 (6) , 2689-2707
Abstract
Dual-flow-loop two-filter radon detectors have a slow time response, which can affect the interpretation of their output when making continuous observations of near-surface atmospheric radon concentrations. While concentrations are routinely reported hourly, a calibrated model of detector performance shows that ∼ 40 % of the signal arrives more than an hour after a radon pulse is delivered. After investigating several possible ways to correct for the detector's slow time response, we show that a Bayesian approach using a Markov chain Monte Carlo sampler is an effective method. After deconvolution, the detector's output is redistributed into the appropriate counting interval and a 10 min temporal resolution can be achieved under test conditions when the radon concentration is controlled. In the case of existing archived observations, collected under less ideal conditions, the data can be retrospectively reprocessed at 30 min resolution. In one case study, we demonstrate that a deconvolved radon time series was consistent with the following: measurements from a fast-response carbon dioxide monitor; grab samples from an aircraft; and a simple mixing height model. In another case study, during a period of stable nights and days with well-developed convective boundary layers, a bias of 18 % in the mean daily minimum radon concentration was eliminated by correcting for the instrument response.Keywords
All Related Versions
This publication has 88 references indexed in Scilit:
- Characterising terrestrial influences on Antarctic air masses using Radon-222 measurements at King George IslandAtmospheric Chemistry and Physics, 2014
- Odeint – Solving Ordinary Differential Equations in C++AIP Conference Proceedings, 2011
- Separating remote fetch and local mixing influences on vertical radon measurements in the lower atmosphereTellus B: Chemical and Physical Meteorology, 2011
- EDDY COVARIANCE CO2 FLUX MEASUREMENTS IN NOCTURNAL CONDITIONS: AN ANALYSIS OF THE PROBLEMEcological Applications, 2008
- Baseline air mass selection at Cape Point, South Africa: application of 222Rn and other filter criteria to CO2Atmospheric Environment, 2004
- Cape Point GAW Station 222Rn detector: factors affecting sensitivity and accuracyAtmospheric Environment, 2002
- European greenhouse gas emissions estimated from continuous atmospheric measurements and radon 222 at Mace Head, IrelandJournal of Geophysical Research: Atmospheres, 2000
- Penetration of Nanometer-Sized Aerosol Particles Through Wire Screen and Laminar Flow TubeAerosol Science and Technology, 1997
- Three‐dimensional radon 222 calculations using assimilated meteorological data and a convective mixing algorithmJournal of Geophysical Research: Atmospheres, 1996
- HST image restoration developments at the ST‐ECFInternational Journal of Imaging Systems and Technology, 1995