Diagnostic Techniques of a Small-Break Loss-of-Coolant Accident at a Pressurized Water Reactor Plant

Authors:

Abstract
A real-time accident tracking calculation technique is investigated for in-depth diagnoses of internal state variables of a pressurized water reactor (PWR) plant in the case of a small-break loss-of-coolant accident (SBLOCA). The technique is composed of two parts: (a) a faster-than-real-time open-system simulator TOKRAC for calculating postaccident thermal-hydraulic behavior in the primary system of a PWR plant, and (b) several real-time state estimators for supplying the unobserved external input to TOKRAC. Observed and unobserved variables are defined as variables that are or are not directly measured by existing plant instrumentation. The external input to the open-system TOKRAC is assumed to be composed of several observed signals and several unobserved state variables: The former are the injection conditions of the emergency core cooling system and the operator actions, while the latter include the total heat transfer rate from the primary to the secondary side in the steam generator (SG) (S...

This publication has 9 references indexed in Scilit: