Inadequacy of Standard Screen Resolution for Localization of Seizures Recorded from Intracranial Electrodes
Abstract
Seizures recorded during long-term monitoring with implanted intracranial electrodes are typically interpreted by visual inspection alone by using digital display systems. When high-frequency activity is digitized and displayed on a typical monitor, it is altered in ways that are not always appreciated and that may have an impact on the intracranial EEG (ICEEG) interpretation. We describe a case of a neocortical-onset seizure in which false localization occurred with a 12-s per screen display. Because frequencies in excess of 100 Hz are not uncommon in neocortical seizures, at most 4 to 5 s of EEG, depending on the screen resolution, data-sampling rate, and other factors, should be displayed at one time during visual interpretation to localize the seizure onset. Alternatively, spectral analysis should be performed on recordings of neocortical seizures to detect high-frequency activity that may be missed on visual inspection.Keywords
This publication has 14 references indexed in Scilit:
- Aliasing in the visual EEG: a potential pitfall of video display technologyClinical Neurophysiology, 2003
- Quantitative Analysis of High-Frequency Oscillations (80–500 Hz) Recorded in Human Epileptic Hippocampus and Entorhinal CortexJournal of Neurophysiology, 2002
- A Possible Role for Gap Junctions in Generation of Very Fast EEG Oscillations Preceding the Onset of, and Perhaps Initiating, SeizuresEpilepsia, 2001
- A Possible Role for Gap Junctions in Generation of Very Fast EEG Oscillations Preceding the Onset of, and Perhaps Initiating, SeizuresEpilepsia, 2001
- Neocortical Temporal Lobe Epilepsy: Intracranial EEG Features and Surgical OutcomeJournal Of Clinical Neurophysiology, 1999
- High-frequency oscillations in human brainHippocampus, 1999
- Power spectrum and intracranial EEG patterns at seizure onset in partial epilepsyElectroencephalography and Clinical Neurophysiology, 1995
- Principles of digital sampling of a physiologic signalElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1993
- High-Frequency EEG Activity at the Start of SeizuresJournal Of Clinical Neurophysiology, 1992
- Very high-frequency rhythmic activity during SEEG suppression in frontal lobe epilepsyElectroencephalography and Clinical Neurophysiology, 1992