Assessment of cardiac output changes using a modified FloTrac/Vigileo™ algorithm in cardiac surgery patients
Open Access
- 4 March 2009
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 13 (2) , R32
Abstract
Introduction: The FloTrac/Vigileo™ (Edwards Lifesciences, Irvine, CA, USA) allows pulse pressure-derived cardiac output measurement without external calibration. Software modifications were performed in order to eliminate initially observed deficits. The aim of this study was to assess changes in cardiac output determined by the FloTrac/Vigileo™ system (FCO) with an initially released (FCOA) and a modified (FCOB) software version, as well as changes in cardiac output from the PiCCOplus™ system (PCO; Pulsion Medical Systems, Munich, Germany). Both devices were compared with cardiac output measured by intermittent thermodilution (ICO). Methods: Cardiac output measurements were performed in patients after elective cardiac surgery. Two sets of data (A and B) were obtained using FCOA and FCOB in 50 patients. After calibration of the PiCCOplus™ system, triplicate FCO and PCO values were recorded and ICO was determined in the supine position and cardiac output changes due to body positioning were recorded 15 minutes later (30° head-up, 30° head-down, supine). Student's t test, analysis of variance and Bland-Altman analysis were calculated. Results: Significant changes of FCO, PCO and ICO induced by body positioning were observed in both data sets. For set A, ΔFCOA was significantly larger than ΔICO induced by positioning the head down. For set B, there were no significant differences between ΔFCOB and ΔICO. For set A, increased limits of agreement were found for FCOA-ICO when compared with PCO-ICO. For set B, mean bias and limits of agreement were comparable for FCOB-ICO and PCO-ICO. Conclusions: The modification of the FloTrac/Vigileo™ system resulted in an improved performance in order to reliably assess cardiac output and track the related changes in patients after cardiac surgery.Keywords
This publication has 24 references indexed in Scilit:
- Cardiac Output Monitoring: Comparison of a New Arterial Pressure Waveform Analysis to the Bolus Thermodilution Technique in Patients Undergoing Off-Pump Coronary Artery Bypass SurgeryJournal of Cardiothoracic and Vascular Anesthesia, 2008
- Cardiac Output Measurement in Patients Undergoing Liver Transplantation: Pulmonary Artery Catheter Versus Uncalibrated Arterial Pressure Waveform AnalysisAnesthesia & Analgesia, 2008
- Cardiac Output Derived from Arterial Pressure Waveform Analysis in Patients Undergoing Cardiac Surgery: Validity of a Second Generation Device: RetractedAnesthesia & Analgesia, 2008
- Cardiac Output Measured by a New Arterial Pressure Waveform Analysis Method Without Calibration Compared With Thermodilution After Cardiac SurgeryJournal of Cardiothoracic and Vascular Anesthesia, 2007
- Comparison of FloTrac™ cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurementsEuropean Journal of Anaesthesiology, 2007
- What technique should I use to measure cardiac output?Current Opinion in Critical Care, 2007
- Agreement between PiCCO pulse‐contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off‐pump coronary artery by‐pass surgeryActa Anaesthesiologica Scandinavica, 2006
- Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysisJournal of Clinical Anesthesia, 2005
- A Randomized, Controlled Trial of the Use of Pulmonary-Artery Catheters in High-Risk Surgical PatientsNew England Journal of Medicine, 2003
- The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT InvestigatorsJAMA, 1996