The Test-Retest Reliability of Anatomical Co-Ordinate Axes Definition for the Quantification of Lower Extremity Kinematics During Running
Open Access
- 1 December 2012
- journal article
- Published by Termedia Sp. z.o.o. in Journal of Human Kinetics
- Vol. 35 (1) , 15-25
Abstract
Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which will produce in-consistent joint rotations. This had led some to question the efficacy of this technique. The aim of the current investigation was to assess the reliability of the anatomical frame definition when quantifying 3-D kinematics of the lower extremities during running. Ten participants completed five successful running trials at 4.0 m·s-1 ± 5%. 3-D angular joint kinematics parameters from the hip, knee and ankle were collected using an eight camera motion analysis system. Two static calibration trials were captured. The first (test) was conducted prior to the running trials following which anatomical landmarks were removed. The second was obtained following completion of the running trials where anatomical landmarks were re-positioned (retest). Paired samples t-tests were used to compare 3-D kinematic parameters quantified using the two static trials, and intraclass correlations were employed to examine the similarities between the sagittal, coronal and transverse plane waveforms. The results indicate that no significant (p>0.05) differences were found between test and retest 3-D kinematic parameters and strong (R2≥0.87) correlations were observed between test and retest waveforms. Based on the results obtained from this investigation, it appears that the anatomical co-ordinate axes of the lower extremities can be defined reliably thus confirming the efficacy of studies using this technique.Keywords
This publication has 15 references indexed in Scilit:
- Influence of the helical and six available Cardan sequences on 3D ankle joint kinematic parametersSports Biomechanics, 2012
- The reliability of three-dimensional kinematic gait measurements: A systematic reviewGait & Posture, 2009
- Assessment of the kinematic variability among 12 motion analysis laboratoriesGait & Posture, 2009
- Discrepancies in Knee Joint Moments Using Common Anatomical Frames Defined by Different Palpable LandmarksJournal of Applied Biomechanics, 2008
- Human movement analysis using stereophotogrammetryGait & Posture, 2005
- A comparison of within‐ and between‐day reliability of discrete 3D lower extremity variables in runnersJournal of Orthopaedic Research, 2002
- Surface-marker cluster design criteria for 3-D bone movement reconstructionIEEE Transactions on Biomedical Engineering, 1997
- Position and orientation in space of bones during movement: anatomical frame definition and determinationClinical Biomechanics, 1995
- AIM project A2002: CAMARC-II (computer aided movement analysis in a rehabilitation context-II)Computer Methods and Programs in Biomedicine, 1994
- The movement of the heel within a running shoeMedicine & Science in Sports & Exercise, 1992