A new iterative algorithm for ring artifact reduction in CT using ring total variation
- 20 September 2019
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 46 (11) , 4803-4815
Abstract
Purpose: In computed tomography (CT), miscalibrated or imperfect detector elements produce stripe artifacts in the sinogram. The stripe artifacts in Radon space are responsible for concentric ring artifacts in the reconstructed images. In this work, a novel optimization model is proposed to remove the ring artifacts in an iterative reconstruction procedure.Method: In the proposed optimization model, a novel ring total variation (RTV) regularization is developed to penalize the ring artifacts in the image domain. Moreover, to correct the sinogram, a new correcting vector is proposed to compensate for malfunctioning of detectors in the projection domain. The optimization problem is solved by using the alternating minimization scheme (AMS). In each iteration, the fidelity term along with the RTV regularization is solved using the alternating direction method of multipliers (ADMM) to find the image, and then the correcting coefficient vector is updated for certain detectors according to the obtained image. Because the sinogram and the image are simultaneously updated, the proposed method basically performs in both image and sinogram domains.Results: The proposed method is evaluated using both simulated and physical phantom datasets containing different ring artifact patterns. In the simulated datasets, the Shepp–Logan phantom, a real chest scan image and a noisy low‐contrast phantom are considered for the performance evaluation of our method. We compare the quantitative root mean square error (RMSE) and structural similarity (SSIM) results of our algorithm with wavelet‐Fourier sinogram filtering method by Munch et al., the ring artifact reduction method by Brun et al., and the TV‐based ring correction method by Paleo and Mirone. Our proposed method is also evaluated using a physical phantom dataset where strong ring artifacts are manifest due to the miscalibration of a large number of detectors. Our proposed method outperforms the competing methods in terms of both qualitative and quantitative evaluation results.Conclusion: The experimental results in both simulated and physical phantom datasets show that the proposed method achieves the state‐of‐the‐art ring artifact reduction performance in terms of RMSE, SSIM, and subjective visual quality.Keywords
Funding Information
- National Institutes of Health (EB017140)
This publication has 17 references indexed in Scilit:
- Ring artifacts correction in compressed sensing tomographic reconstructionJournal of Synchrotron Radiation, 2015
- On the Convergence of Alternating Minimization for Convex Programming with Applications to Iteratively Reweighted Least Squares and Decomposition SchemesSIAM Journal on Optimization, 2015
- Edge adaptive directional total variationThe Journal of Engineering, 2013
- Distributed Optimization and Statistical Learning via the Alternating Direction Method of MultipliersFoundations and Trends in Machine Learning, 2011
- Removal of ring artifacts in CT imaging through detection and correction of stripes in the sinogramPhysics in Medicine & Biology, 2010
- A prioriinformation in a regularized sinogram-based method for removing ring artefacts in tomographyJournal of Synchrotron Radiation, 2010
- Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithmsPhysics in Medicine & Biology, 2009
- Stripe and ring artifact removal with combined wavelet—Fourier filteringOptics Express, 2009
- An improved method for ring artifacts removing in reconstructed tomographic images2009
- Nonlinear total variation based noise removal algorithmsPhysica D: Nonlinear Phenomena, 1992