Distortions in Electrochemical Impedance Spectroscopy Measurements Using 3‐Electrode Methods in SOFC. I – Effect of Cell Geometry
Authors:
- 22 October 2007
- journal article
- research article
- Published by Wiley in Fuel Cells
- Vol. 7 (5) , 364-376
Abstract
The use of a reference electrode (RE) is necessary to independently measure the overpotential of each electrode in solid oxide fuel cells (SOFC). This type of set‐up, known as the 3‐electrode (or 3‐terminal) configuration, can give erroneous results if the RE does not effectively separate the potential of the two active electrodes. In this work, calculations and experiments were performed to verify the effectiveness of the 3‐electrode configuration used in electrochemical impedance spectroscopy (EIS) measurements for studying the kinetics of anodes and cathodes in SOFC. Initially, a theoretical analysis of the impedance distortions in relation to the electrode geometry and configuration is presented and the main causes of distortions are elucidated. Then, this analysis is corroborated by experimental results obtained using two specially designed cells. Calculations and experiments reconfirm that configurations characterised by electrodes of equal area and symmetrical placement do not produce EIS distortions when the electrodes have similar area‐specific polarisation resistances and time constants. Moreover, distortions can be low even in considerably misaligned configurations when electrodes are small and relatively inactive.Keywords
This publication has 25 references indexed in Scilit:
- Distortions in Electrochemical Impedance Spectroscopy Measurements Using 3‐Electrode Methods in SOFC. II. Effect of Electrode Activity and Relaxation TimesFuel Cells, 2007
- Analytical Solution for the Impedance of a Porous ElectrodeJournal of the Electrochemical Society, 2004
- The two-terminal equivalent network of a three-terminal electrochemical cellElectrochemistry Communications, 2001
- The Influence of Current Constriction on the Impedance of Polarizable Electrodes: Application to Fuel Cell ElectrodesJournal of the Electrochemical Society, 1997
- Inductive Loops in Impedance Spectroscopy Caused by Electrical ShieldingJournal of the Electrochemical Society, 1996
- Experimental limitations in impedance spectroscopy: Part I - simulation of reference electrode artifacts in three-point measurementsSolid State Ionics, 1996
- Experimental limitations in impedance spectroscopy: Part II — electrode artifacts in three-point measurements on Pt/YSZSolid State Ionics, 1996
- Evaluation of commercial zirconia powders forsolid oxide fuel cellsSolid State Ionics, 1994
- Impedance studies of porous electrodesElectrochimica Acta, 1990
- Influence of electrode geometry and NLLS fit analysis of I-V measurements in a three-electrode cellSolid State Ionics, 1988