Continuous Glucose Monitoring System Based on Percutaneous Microneedle Array
Open Access
- 20 March 2022
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 13 (3) , 478
Abstract
A continuous blood glucose monitoring system (CGMS) which include a microneedle-array blood glucose sensor, a circuit module, and a transmission module placed in a wearable device is developed in this research. When in use, the wearable device is attached to the human body with the microneedle array inserted under the skin for continuous blood glucose sensing, and the measured signals are transmitted wirelessly to a mobile phone or computer for analysis. The purpose of this study is to replace the conventionally used method of puncture for blood collection and test strips are used to measure the blood glucose signals. The microneedle sensor of this CGMS uses a 1 mm length needle in a 3 mm × 3 mm microneedle array for percutaneous minimally invasive blood glucose measurement. This size of microneedle does not cause bleeding damage to the body when used. The microneedle sensor is placed under the skin and their solutions are discussed. The blood glucose sensor measured the in vitro simulant fluid with a glucose concentration range of 50~400 mg/dL. In addition, a micro-transfer method is developed to accurately deposit the enzyme onto the tip of the microneedle, after which cyclic voltammetry (CV) is used to measure the glucose simulation solution to verify whether the difference in the amount of enzyme on each microneedle is less than 10%. Finally, various experiments and analyses are carried out to reduce the size of the device, test effective durability (approximately 7 days), and the feasibility of minimally invasive CGMS is evaluated by tests on two persons.Keywords
This publication has 18 references indexed in Scilit:
- Continuous glucose monitoring: A review of the technology and clinical useDiabetes Research and Clinical Practice, 2017
- Factory-Calibrated Continuous Glucose Sensors: The Science Behind the TechnologyDiabetes Technology & Therapeutics, 2017
- Materials used to simulate physical properties of human skinSkin Research and Technology, 2015
- Continuous Glucose Monitoring Systems: A ReviewDiagnostics, 2013
- The International Diabetes Federation diabetes atlas methodology for estimating global and national prevalence of diabetes in adultsDiabetes Research and Clinical Practice, 2011
- Microneedle array-based carbon paste amperometric sensors and biosensorsThe Analyst, 2011
- Possibilities for continuous glucose monitoring by a functional contact lensIEEE Instrumentation & Measurement Magazine, 2010
- Low potential stable glucose detection at dendrimers modified polyaniline nanotubesMaterials Research, 2010
- Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System During HypoglycemiaDiabetes Care, 2004
- First human experiments with a novel non-invasive, non-optical continuous glucose monitoring systemBiosensors and Bioelectronics, 2003