Using force data to self-pace an instrumented treadmill and measure self-selected walking speed
Authors:
Open Access
- 3 June 2020
- journal article
- research article
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 17 (1) , 1-14
Abstract
Background: Self-selected speed is an important functional index of walking. A self-pacing controller that reliably matches walking speed without additional hardware can be useful for measuring self-selected speed in a treadmill-based laboratory. Methods: We adapted a previously proposed self-pacing controller for force-instrumented treadmills and validated its use for measuring self-selected speeds. We first evaluated the controller’s estimation of subject speed and position from the force-plates by comparing it to those from motion capture data. We then compared five tests of self-selected speed. Ten healthy adults completed a standard 10-meter walk test, a 150-meter walk test, a commonly used manual treadmill speed selection test, a two-minute self-paced treadmill test, and a 150-meter self-paced treadmill test. In each case, subjects were instructed to walk at or select their comfortable speed. We also assessed the time taken for a trial and a survey on comfort and ease of choosing a speed in all the tests. Results: The self-pacing algorithm estimated subject speed and position accurately, with root mean square differences compared to motion capture of 0.023 m s −1 and 0.014 m, respectively. Self-selected speeds from both self-paced treadmill tests correlated well with those from the 10-meter walk test (R>0.93,p−13). Subjects walked slower on average in the self-paced treadmill tests (1.23±0.27 ms−1) than in the 10-meter walk test (1.32±0.18 ms−1) but the speed differences within subjects were consistent. These correlations and walking speeds are comparable to those from the manual treadmill speed selection test (R=0.89,p=3×10−11;1.18±0.24 ms−1). Comfort and ease of speed selection were similar in the self-paced tests and the manual speed selection test, but the self-paced tests required only about a third of the time to complete. Our results demonstrate that these self-paced treadmill tests can be a strong alternative to the commonly used manual treadmill speed selection test. Conclusions: The self-paced force-instrumented treadmill well adapts to subject walking speed and reliably measures self-selected walking speeds. We provide the self-pacing software to facilitate use by gait researchers and clinicians.Keywords
All Related Versions
This publication has 39 references indexed in Scilit:
- Comparison of walking overground and in a Computer Assisted Rehabilitation Environment (CAREN) in individuals with and without transtibial amputationJournal of NeuroEngineering and Rehabilitation, 2012
- A novel walking speed estimation scheme and its application to treadmill control for gait rehabilitationJournal of NeuroEngineering and Rehabilitation, 2012
- Distinct fast and slow processes contribute to the selection of preferred step frequency during human walkingJournal of Applied Physiology, 2011
- Controlling the Walking Speed in Limit Cycle WalkingThe International Journal of Robotics Research, 2008
- Relationship Between Test Methodology and Mean Velocity in Timed Walk Tests: A ReviewArchives of Physical Medicine and Rehabilitation, 2008
- Biomechanics of overground vs. treadmill walking in healthy individualsJournal of Applied Physiology, 2008
- Improvement in Usual Gait Speed Predicts Better Survival in Older AdultsJournal of the American Geriatrics Society, 2007
- A Treadmill and Motion Coupled Virtual Reality System for Gait Training Post-StrokeCyberPsychology & Behavior, 2006
- Rhythmic auditory-motor facilitation of gait patterns in patients with Parkinson's disease.Journal of Neurology, Neurosurgery & Psychiatry, 1997
- Comfortable and maximum walking speed of adults aged 20—79 years: reference values and determinantsAge and Ageing, 1997